If High Temperature Management is Enabled
When the internal temperature of any disk drive rises above the high temperature threshold,
FastTrace-R will initiate an over-temperature condition and generate an alarm. The FastTrace-R
fault relay will activate during the over-temperature condition. The FastTrace-R will continue to
operate normally after reporting the over temperature condition but urgent action must be taken
to ensure that the ambient temperature complies with FastTrace-R's 40°C maximum operating
temperature specification. Continued operation at a temperature exceeding the specified
maximum may damage or reduce the useable life of FastTrace-R.
When the temperature falls below the low temperature threshold, the over-temperature condition
will be cleared and the fault relay will de-activate.
If High Temperature Management is Disabled
No over-temperature alarm will be generated and the fault relay will not activate for an over-
temperature condition. The unit will continue normal recording.
Note: It is recommended that only specified hard disk drives recommended by ADPRO
personnel be used. If non recommended hard disk drives are installed, temperature
information received from the drive used for temperature management may be
erroneous, causing damage to the FastTrace-R and/or incorrect reporting of alarms.
Zone Isolate
The Zone Isolate feature allows a central monitoring station operator to prevent an alarm
detector from generating alarms. This feature is useful in a number of scenarios:
• Commissioning a FastTrace-R
• Fault finding an installation
• Configuring detectors
• Disabling faulty detectors
Any VideoCentral operator is able to view the current state of detectors on the connected
FastTrace-R. However, only CMS operators can modify Zone Isolate status. Observers are
locked out from any Zone Isolate capability. The isolation status of a zone will persist after a
reboot of the FastTrace-R, allowing the installer to rectify any detector problem before the
detector is unisolated.
Zone Isolate Reminder
If zones are isolated on FastTrace-R, then a periodic reminder can be generated by FastTrace-R
to highlight upon connection, this fact to an operator.