User manual

Installation and User Manual ADPRO FastTrace-R by Xtralis
90 Doc 13972_03
Use the Selection Method drop-down box to determine how the modes will be changed (either
via an input change or by day / time calendar selection) and press the Configure… button to
define the operation.
The Use External Input to Change Modes option is used to configure switching between two
modes via the use of the Mode Select Input on the rear panel of the unit (Pin 9 of the General I/
O connector). Of the four available modes, any two can be assigned. For example, Mode 2 is
assigned to an Open input and Mode 3 to a Closed input. When the Mode Select Input pin
changes state, so does the operational mode of the FastTrace-R between Mode 2 and Mode 3.
For example, an alarm panel that latches an output contact state when setting and unsetting the
system may provide the contact change. In this instance the operational modes of the FastTrace-
R system would follow the status of the Alarm panel.
Use the Configure button to open the Input Mode Selection dialog box and choose which
Mode is to be assigned when the contact is Open and another Mode for assignment to a Closed
contact condition.
Figure 87: Changing Modes Via an Input
Alternatively, the Specify Mode Changes in a Calendar option can be selected when users
require access to different modes on a time schedule basis. This option provides a timetable,
using time blocks of 15 minutes duration, to assign different modes to individual time blocks, or
groups of blocks, to provide the FastTrace-R with a great degree of operational flexibility.
Use the Configure button to open the Mode Calendar Settings dialog box.
Figure 88: Changing Modes Via Calendar