ADPRO FastTrace-R by Xtralis Installation and User Manual March 16, 2010 Doc.
ADPRO FastTrace-R by Xtralis Installation and User Manual Disclaimer The contents of this document are provided on an "as is" basis. No representation or warranty (either express or implied) is made as to the completeness, accuracy or reliability of the contents of this document. The manufacturer reserves the right to change designs or specifications without obligation and without further notice.
Installation and User Manual ADPRO FastTrace-R by Xtralis The following icons are used in this document Convention Description Caution: This icon is used to indicate that there is a danger to equipment. The danger could be loss of data, physical damage, or permanent corruption of configuration details. Warning: This icon is used to indicate that there is a danger of electric shock. This may lead to death or permanent injury.
ADPRO FastTrace-R by Xtralis Installation and User Manual Contact Us The Americas +1 781 740 2223 Asia +852 2916 8894 Australia and New Zealand +61 3 9936 7000 Continental Europe +32 56 24 19 51 UK and the Middle East +44 1442 242 330 www.xtralis.com Doc.
Installation and User Manual ADPRO FastTrace-R by Xtralis Declaration of Conformity Manufacturer's Name: Manufacturer's Address: Xtralis AG Pty Ltd 4 North Drive, Virginia Park 236-262 East Boundary Road Bentleigh East VIC 3165 Australia. declares, that the product(s): Product Name: Model Number: ADPRO FastTrace-R Video Security System AFT-5020-X-Y-D-R AFT-5010-X-Y-D-R X = Number of Hard Disk Drives between 1 - 4. Y = Number of Video Compression Engines between 1 - 4.
ADPRO FastTrace-R by Xtralis Installation and User Manual Contents 1 Introduction ...............................................................................................................................1 2 FastTrace-R Setup Instructions ...............................................................................................3 2.1 Physical Location ...........................................................................................................3 2.2 General Power Requirements .
Installation and User Manual 3.4.1 ADPRO FastTrace-R by Xtralis Video Input Requirements ................................................................................ 36 3.5 Video Output ................................................................................................................. 37 3.6 Configuration Switches ................................................................................................ 37 3.7 Alarm Inputs .....................................................
ADPRO FastTrace-R by Xtralis 5 Installation and User Manual Event Log ............................................................................................................................... 107 5.1 Save the Event Log ..................................................................................................... 108 5.2 Severity and Visibility Levels ..................................................................................... 109 6 FastTrace-R Impounding ........................
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 34: Audio D-Connector Pinouts ................................................................................................ 31 Figure 35: Audio Connector Pinouts .................................................................................................... 32 Figure 36: Audio Configuration with Amplifier ...................................................................................... 33 Figure 37: Microphone Connection........
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 91: Video Capture Settings ....................................................................................................... 93 Figure 92: Video Capture Settings ....................................................................................................... 93 Figure 93: Event Trigger Settings.........................................................................................................
Installation and User Manual ADPRO FastTrace-R by Xtralis Doc.
ADPRO FastTrace-R by Xtralis 1 Installation and User Manual Introduction ADPRO FastTrace-R by Xtralis is an advanced, high performance digital video and audio recorder optimised for remote search and playback. Available in a number of models with 10 or 20 video inputs, FastTrace-R provides outstanding transmission speed and picture quality for remote security and surveillance applications where secure, event-driven recording from multiple cameras onto digital data storage disks is required.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 1: Typical FastTrace-R Application 2 Doc.
ADPRO FastTrace-R by Xtralis 2 Installation and User Manual FastTrace-R Setup Instructions This chapter contains instructions to setup the FastTrace-R. 2.1 Physical Location The location within the protected premises of the FastTrace-R should be considered carefully and the following notes are provided for guidance. • Physical Security - The FastTrace-R should be located where it will remain secure under all conditions, even when the premises are open or occupied.
Installation and User Manual Caution: ADPRO FastTrace-R by Xtralis The FastTrace-R is a Class 1 electrical product and must always be connected to a grounded power outlet. Always ensure that FastTrace-R is installed adjacent to a grounded power outlet. 2.2.1 Power Conditioners and Surge Arresters The use of an Uninterruptible Power Supply (UPS) should be considered in situations where the mains power is unreliable.
ADPRO FastTrace-R by Xtralis Note: Installation and User Manual The foil used in some shielded cable is only insulated on one side. Always check the foil shield with an ohm-meter and make sure that the conductive side is in contact with shield termination recommendations in this manual. FCC Advice for Installers and Users in the United States FastTrace-R equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Installation and User Manual ADPRO FastTrace-R by Xtralis This permanent earth connection point is an M4 tapped insert on the metalwork and is supplied with a screw and washer as shown below. Figure 2: FastTrace-R Grounding Requirements Connect this earth point to a protective earth point in the system installation using 2.5 mm 2 wire (minimum) and suitable ring terminals. The installation protective earth point must be installed in accordance with local electrical installation codes and requirements.
ADPRO FastTrace-R by Xtralis Installation and User Manual To complete FastTrace-R installation, you may need: • • • Null modem cable Camera and coax cable External alarm switches or other devices • PC or Laptop running Microsoft Windows 2000 Professional or Windows XP Professional, with an Ethernet Port or a serial port and a DVD drive. ® 2.5 ® ® Mounting the FastTrace-R 2.5.
Installation and User Manual 2.7 ADPRO FastTrace-R by Xtralis Setting up the PC To set up the FastTrace-R for operation, it must be connected to a PC installed with the latest version of VideoCentral Lite or Gold. Contact your ADPRO supplier or sales office for details. Connection to the FastTrace-R may be via an Ethernet crossover cable (supplied), via the Ethernet port on the rear of the FastTrace-R, or via a null modem cable (not supplied), via the Comms 2 port on the rear of the FastTrace-R.
ADPRO FastTrace-R by Xtralis Installation and User Manual 2.7.3 Configuring the PC for Ethernet Connection A crossover Category 5 Ethernet cable is supplied for connection between the PC’s network port and the FastTrace-R Ethernet (Network) port. This cable must be connected between the PC and FastTrace-R prior to powering on the FastTrace-R. The (factory) TCP/IP network address for the FastTrace-R is: 192.168.1.1 The (factory) subnet mask address is 255.255.255.
Installation and User Manual ADPRO FastTrace-R by Xtralis 2.7.4 Configuring the PC for Serial Connection Note: The following procedure is only required if you have a null modem cable and do not intend to use the crossover ethernet cable to connect to the FastTrace-R. (Refer to Section 2 - Null-Modem Cable Wiring for wiring details for the null modem cable). The serial comms (COM) port on the PC must be configured for operation as follows: 1. Select Control Panel / System / Hardware tab.
ADPRO FastTrace-R by Xtralis 3. Installation and User Manual Double click on the required communications port (COM1 or COM2). Figure 8: COM Port Settings 4. 5. 6. Select the Port Settings tab and enter the following settings: Bits per second = 115,200 bps Data bits = 8 Parity = none Stop bits = 1 Flow control = hardware Ensure the FastTrace-R is free-standing with no obstruction to airflow (cooling fan at rear). Connect the cable between the FastTrace-R COMMS 2 port and the PC's serial port.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 9: Phone and Modem Options 4. Click on the Modems tab and select the Add button. Figure 10: Install New Modem 5. 12 When the Install New Modem dialog box is displayed, click the Don't detect my modem, I will select it from a list checkbox, then click Next.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 11: Select Modem Driver from Disk 6. Click the Have Disk button. The Install From Disk screen is displayed. Figure 12: Install from Disk 7. 8. Doc 13972_03 Select the Browse button, navigate to the CD drive and select Drivers and Libraries / Null Modem Driver / mdmcisc2.inf (note that the CDROM should still be in the drive). Select Open and click OK.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 13: Select Modem COM Port 9. Click Next and select either COM1 or COM2 (but not both). 10. Click Next, the following screen will display. Figure 14: Installation Warning 11. Select Continue Anyway and click Finish when the software has installed. Reboot the PC to ensure the serial comms and modem driver changes become active.
ADPRO FastTrace-R by Xtralis Installation and User Manual Null-modem Cable Wiring Should it be necessary to use a null-modem cable that is longer than that supplied with the FastTrace-R, use the diagram shown to make a longer cable. Note: RS232 cables should never extend past 15m (33 feet). Figure 15: Null-Modem Wiring 2.7.5 Installing VideoCentral Lite Software 1. Start the PC and insert the CD into the appropriate CD drive.
Installation and User Manual 2. ADPRO FastTrace-R by Xtralis Select VideoCentral Lite, the following window is displayed. Figure 17: Setup Wizard Introduction Screen 3. 4. After checking that the version number that you are upgrading to is correct, click Next. At any point during the installation, you can go back any number of steps by clicking Back. Check that the location shown is where you wish to install VideoCentral. If it is correct, click Next, otherwise browse and select the location.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 19: Transmitter Alarm Management 5. Select Yes and click Next. Figure 20: Communication Devices 6. Select the checkbox next to the device you are using to enable VideoCentral Lite to connect to the FastTrace-R unit (Network Adaptor for an ethernet connection, Generic NULL Modem for a serial connection). Click Next. Note: 7. 8. Doc 13972_03 If you wish to change the option, you must first DESELECT the current device.
Installation and User Manual ADPRO FastTrace-R by Xtralis The screen below is displayed when the installation is complete: Figure 21: Setup Complete Note: The PC must be restarted before VideoCentral Lite can be used. 2.7.6 Starting VideoCentral Lite for the First Time 1. Start the VideoCentral Lite program by double-clicking the VideoCentral icon on the Windows desktop. If you do not have a VideoCentral dongle (Hardware Protection Key) attached to the PC, the following screen will appear.
ADPRO FastTrace-R by Xtralis 3. Installation and User Manual To check the defaults, select the FT-R default site entry and click Edit. The Site Configuration details are shown with the default values, as follows: Figure 23: Default Ethernet Site Configuration Figure 24: Default Serial Site Configuration 2.8 1. FastTrace-R Configuration Before powering the FastTrace-R unit on, check that the factory DIP-Switch settings are correct refer to Section 3 for more details.
Installation and User Manual ADPRO FastTrace-R by Xtralis 2.8.1 Powering Up the FastTrace-R The green Power and the red Status LEDs on the front panel are lit as soon as power is applied to the unit. The FastTrace-R is supplied with a universal input power supply that operates from 100-240V AC, 50-60Hz. There are no switches to change based upon your particular mains power voltage or frequency.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 25: Connect To Site The VideoCentral User Interface screen will be displayed and if a camera has been connected, there should be video displayed, otherwise a standard blue screen is shown.
Installation and User Manual 7. ADPRO FastTrace-R by Xtralis Go to the Connection menu and click the Installer Menu option (or click the Installer Menu button on the Site Actions flyout). Figure 27: Installer Menu Button The Setup files will be downloaded from the FastTrace-R unit. Note: The first time the settings are accessed, it may take some time to download the settings as the setup program is also being downloaded from the FastTrace-R unit.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 28: FastTrace-R User Settings Setup parameters and configuration options for the FastTrace-R can now be modified. Refer to Section 4 - Programming FastTrace-R for details of the settings which must be defined to use the FastTrace-R in an operational environment. 8. Define all required FastTrace-R user settings and select the Save to FT-R button.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 29: Configure a New Site 2. 3. 4. Enter the following details for the FastTrace-R unit: Site Id: 9 characters (max) - this is the name of the FastTrace-R unit CMS Password: 8 characters (max) Communications: Network For the Network selection, enter a valid IP address for the FastTrace-R Click OK. The configure Site dialog box is shown again. Click Close. The System Administration options are then shown. Click Exit.
ADPRO FastTrace-R by Xtralis Installation and User Manual 2.12 Notes and Troubleshooting Tips • • Ensure that details entered at VideoCentral AND the FastTrace-R are IDENTICAL. Ensure the TCP/IP address and subnet mask are correct. 2.12.1 Setting the Date and Time The FastTrace-R uses a stable internal clock that is based on UTC (Coordinated Universal Time).
Installation and User Manual 9. ADPRO FastTrace-R by Xtralis Save all changes when exiting the User Settings menu. 10. Reset Switch 7 to the OFF position and power cycle the unit. The FastTrace-R will now operate with the new Site ID, Password and Network Address. 2.14 Firewall Configuration If the FastTrace-R unit is connected via a firewall, the following table describes the destination port allocation for the VideoCentral PC and FastTrace-R unit. Source ports are randomly chosen.
ADPRO FastTrace-R by Xtralis 3 Installation and User Manual FastTrace-R Connectors All external connections to the FastTrace-R chassis are made via the rear panel, refer to the following figure: Figure 31: FastTrace-R Connections Doc 13972_03 27
Installation and User Manual 3.1 ADPRO FastTrace-R by Xtralis Power Connection The FastTrace-R is designed for 100-240 VAC 50-60Hz operation. Ensure mains supplies are stable and are not subject to frequency changes, voltage spikes etc. The use of mains suppression units or even UPS (Uninterrupted Power Supply) systems is recommended to ensure stable voltages. Maximum input current is 5 amps during power up and 1 amp during normal operation. Typical unit power consumption when fully optioned is 100 W.
ADPRO FastTrace-R by Xtralis V.24 Name Installation and User Manual Pin Direction 10 I 11 O 12 I 13 I 14 O 15 I 16 I 17 I 18 I 19 O DTR 20 O Data terminal ready RL 21 O Remote loopback RI 22 I Ring Indicator 23 I 24 O 25 | SCT RXC TXC V.24 Description DCE transmit clock DCE receive clock DTE Transmit Clock 3.2.2 COMMS 2 COMMS 2 is used to connect to modems and terminal adaptors to support PSTN and ISDN links at data rates up to 230 kbps.
Installation and User Manual ADPRO FastTrace-R by Xtralis 3.2.3 Connecting to a Modem or TA Communication devices with a V.24 port are connected to the FastTrace-R using the modem cable supplied with the modem or terminal adaptor. Either Comms 1 or Comms 2 may be used and the FastTrace-R can be set up with two communications devices, allowing simultaneous connections and / or a back-up communications path. Figure 33: Modem Connection 3.2.
ADPRO FastTrace-R by Xtralis Note: Installation and User Manual ALWAYS consult with the IT or Network Manager for the network BEFORE physically connecting FastTrace-R to the network. A network address is required for correct operation over a network. Both the FastTrace-R and the PC running the VideoCentral software must have a unique TCP/IP address (referred to as the IP address). A number of IP parameters may need to be entered to correctly identify a FastTrace-R on a network.
Installation and User Manual ADPRO FastTrace-R by Xtralis Table 5: Audio Switcher Connections Pin Function Serial Link for Channel Number selection Signal Pin Specifications Serial Clock 14 Serial Data 7 Open drain output 32 V maximum 100 mA maximum On impedance <15 ohm Serial Strobe Audio Signals 15 not used 8 Audio Out (+) 1 Output impedance >600 ohm Nominal output level = 315 mVrms Audio In (+) 2 Input impedance >6K ohm Nominal level = 10 mVrms to 400 mVrms Audio Common 9 Audio S
ADPRO FastTrace-R by Xtralis Installation and User Manual Table 6: Audio Screw Terminal Connector Pin Function Signal Pin Line Level Audio Output 1 Unbalanced, impedance 600 ohm Nominal voltage level = 315 mVrms Ground 2 0V Input 3 Unbalanced, impedance >6 K ohm Nominal level = 10 mVrms to 400 mVrms Ground 4 Speaker (+) Speaker (-) 5 6 Ground 7 Microphone (+) Microphone (-) 8 9 Local Speaker Local Microphone Specifications Balanced, impedance = 8 ohm Nominal output power = 1 W Tota
Installation and User Manual Audio Input 3 Ground 2 ADPRO FastTrace-R by Xtralis Microphone Pre-amplifier 1 2 3 4 5 6 7 8 9 Audio Connector Port Figure 37: Microphone Connection By using both the audio input and output, intercom systems and handsets can also be connected to the FastTrace-R. When used in conjunction with the alarm inputs this allows the FastTrace-R to be used for help points and door/gate entry systems.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 39: Zoned Audio Configuration 3.4 Video Input Connections Depending on the model, up to 20 video sources can be connected via the female BNC sockets. The sources should generate a 1.0-volt peak to peak composite colour or black and white video signal when terminated with a 75-ohm load. A combination of colour and black and white cameras can be used.
Installation and User Manual Caution: ADPRO FastTrace-R by Xtralis Installations in Lightning Prone Areas In lightning prone areas, in-line coaxial lightning arresters should be used on the video cables. The arresters should be installed at the cable entry of the building that houses the FastTrace-R. Cameras should also have suitable lightning protection rods installed as close to them as possible.
ADPRO FastTrace-R by Xtralis Installation and User Manual Maximum Camera Input Cable Length The maximum cable length that can be used from a camera before cable compensators are required is dictated by the desired quality of the video picture. Generally, the shorter the cable between the camera and the FastTrace-R the better the video picture quality.
Installation and User Manual ADPRO FastTrace-R by Xtralis Table 7: DIP Switch Configuration Switch 1 2 Function On Off Factory Set On Factory Set Off 3 On Off 4 5 6 7 Factory Set On Off Factory Set On RS422 Configuration for PTZ port Off RS485 Configuration for PTZ port On Impounded Off Normal Operating Position On Default override setting for direct connection Note: Refer to FastTrace-R Connection Details Lost for an explanation of this switch functionality.
ADPRO FastTrace-R by Xtralis 3.7 Installation and User Manual Alarm Inputs Unlike other equipment, which typically has statically assigned alarm input to video relationships (i.e. alarm input 1 always related to video channel 1, alarm input 2 always related to video channel 2, etc), FastTrace-R can be programmed so that any one or group of alarm inputs can trigger any one or group of cameras. This allows much more flexibility within system designs and configurations.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 42: Alarm Input Configuration 3.7.1 Driving the Alarm Inputs For an alarm input to be recognised, the input device must hold a changed state for a period of 100 ms. • • For a valid closed contact, the total resistance, including wiring resistance, must be below 150 ohms. For an open contact to be valid the resistance presented at the alarm input must be above 2,500 ohms. The alarm inputs and numbering for all channels is shown below.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 43: Alarm Connector Pinouts Wire connections from the alarm switches are made by using the screw terminal contact strips supplied with the FastTrace-R. For ease of installation, the screw terminal blocks slide over the connector pins when the wiring is complete. Caution: DO NOT attempt to solder directly onto the connector pins, as this may cause heat damage to the connector housing or to the interface PCB.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 44: External Sensor Wiring Circuits Please refer to Specifications for voltage requirements and considerations. 3.8 Control Outputs FastTrace-R has 10 or 20 Control Outputs that can be controlled by a remote operator using VideoCentral. The devices can be used to control operation of lights, gates / doors and control equipment.
ADPRO FastTrace-R by Xtralis Installation and User Manual 3.8.1 Connecting to the Control Outputs Control Outputs are available via screw connection strips on the rear panel. Figure 45: Pinouts for Control Output Connectors Caution: Exceeding the Control Output’s maximum voltage or current rating (12 Vdc, 100 mA) will damage the FastTrace-R and invalidate the product warranty. For high power/voltage equipment, suitable interface circuitry must be used between the Control Outputs and the equipment.
Installation and User Manual ADPRO FastTrace-R by Xtralis A single 9-way D connector is provided on the unit to support RS422 and RS485 connectivity to PTZ camera stations. The connectivity is shown below. To change between RS422 and RS485, use DIP switch 5 on the rear of the unit. To provide termination of the RS485 line use DIP switch 8 on the rear of the unit.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 49: Typical PTZ Configuration 3.9.1 PTZ Port Setup The following points are applicable to the PTZ port. • • • Telemetry stations are connected via a 9-pin D connector, marked ‘PTZ’ RS485 control links allow cable lengths of up to 1000 metres Up to 20 (identical) telemetry stations can be connected to one FastTrace-R Use the following guidelines when connecting and setting up a telemetry station.
Installation and User Manual ADPRO FastTrace-R by Xtralis PTZ Camera Station RS422/485 Port Balanced Transmit/ Receive FastTrace PTZ Port (+) 2 (+) (-) 3 (-) Ground 5 Balanced Transmit/ Receive Ground Shield RS485 ft connection.cdr Figure 50: RS485 PTZ Port Connections to a Telemetry Station • • Make sure the last telemetry station connected to the link is terminated by a 120 ohm resistor.
ADPRO FastTrace-R by Xtralis Installation and User Manual Table 9: General Purpose Serial Port Connections PIN Signal Description 1 DCD Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready 7 RTS Request to send 8 CTS Clear to send 9 RI Ring Indicator Figure 52: Typical Configuration with ATM/EPOS 3.11 Data Connection A single 9-way D connector is provided on the unit for data connection, such as Transparent RS232.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 53: Pin Numbering of the Data Port Table 10: Data Port Connections PIN Signal Description 1 DCD Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready 7 RTS Request to send 8 CTS Clear to send 9 +V Signal High 3.12 Connecting to the General I/O General Inputs/Outputs are available via screw connection strips on the rear panel.
ADPRO FastTrace-R by Xtralis Installation and User Manual 3.12.3 Clock Synchronise - Pin 5 Currently unused. 3.12.4 Push to Talk - Pin 7 Currently unused. 3.12.5 Mode Select Input - Pin 9 The way a FastTrace-R operates its recording and alarm event recording features can be changed by using up to four different operating ‘modes’. The parameters that define a particular mode of operation, such as recording rate and alarm recording responses, are configured by using the FastTrace-R Installer Menu.
Installation and User Manual ADPRO FastTrace-R by Xtralis 3.13 Powering Up the FastTrace-R The FastTrace-R is supplied with a universal input power supply which operates from 100-240 V AC, 50-60 Hz. There are no switches to change based upon your particular mains power voltage or frequency. When power is applied to the FastTrace-R the green LED located on the front panel of the unit will illuminate.
ADPRO FastTrace-R by Xtralis 4 Installation and User Manual Programming FastTrace-R 4.1 Programming Checklist The following checklist provides an overview of the main tasks required to program a FastTraceR and the sequence in which they should be performed: • • • Set the unique Site ID and Password for the FastTrace-R and ensure that matching ones are entered in VideoCentral (refer to Site Details).
Installation and User Manual 4.3 Note: ADPRO FastTrace-R by Xtralis Entering the FastTrace-R Setup Screen Always use extreme caution when remotely programming FastTrace-R units. Changing connection parameters or passwords may result in the VideoCentral system not being able to regain access, resulting in the need for engineering attendance at the site to reprogram the system. Remote programming of FastTrace-R systems is carried out via a screen as shown below.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 56: FastTrace-R User Settings Note: Some options for a category can be affected by the status of other setting(s) and may be unavailable (shown ‘ghosted’). The programming GUI is a separate program to VideoCentral and there are numerous different versions (although outwardly all look the same). The precise version used is dependent upon the software installed on the FastTrace-R system being programmed.
Installation and User Manual ADPRO FastTrace-R by Xtralis 4.3.1 Saving a Configuration to File Selecting the Save to File … button displays the Save As dialog box. • • • Files are saved in a ‘FT-R User Settings (*.fus)’ file format. Characters such as ':', '*' and '?' in the filename are invalid and will not be accepted. If the file already exists, the user shall be asked whether or not they wish to overwrite the existing file.
ADPRO FastTrace-R by Xtralis Installation and User Manual 4.3.3 Site Details Figure 59: Site Details Menu Site ID Each ADPRO FastTrace-R must have a unique site ID. The maximum site ID alpha-numeric length is 9 characters. Note that the ‘local’ site ID entered here must match a site ID entry in the VideoCentral Site List (Database / Administration / Configure Sites). The default site ID is FastTrace-R.
Installation and User Manual ADPRO FastTrace-R by Xtralis 4.3.4 Date/Time Settings To enable accurate event tracking, the FastTrace-R can be set to accommodate local or regional daylight saving time shifts when they affect the location where the FastTrace-R is installed. Figure 60: Date/Time Settings Menu Time Zone Database records within the FastTrace-R are timestamped using Coordinated Universal Time (abbreviated as UTC).
ADPRO FastTrace-R by Xtralis Installation and User Manual Adjusting FastTrace-R Time via VideoCentral If the time zone has been set correctly, as detailed above, but the time at the FastTrace-R is not accurate, the time may be changed via VideoCentral. This may be performed by double clicking on the time and date displayed at VideoCentral while connected to the FastTrace-R.
Installation and User Manual VideoCentral V9.01 or later connecting to FastTrace-R V2.07 or later VideoCentral V9.00 or later connecting to FastTrace-R V2.07 or later VideoCentral prior to V9.00 connecting to FastTrace-R V2.07 or later User attempts to make a large backward time change Urgent warning indicating that a gap will exist in the recorded data. If the user proceeds, the time will be changed.
ADPRO FastTrace-R by Xtralis Installation and User Manual 4.3.5 Licensing The Licensing option enables users to enable the upgrade to a FastTrace-R and Transaction Device (ATM/EPOS) functionality through a license purchased from your distributor. Once the license details are entered, you can then configure the transaction device function. Figure 62: Licensing Settings A Transaction Device can be connected to the FastTrace-R via one of the GP Serial ports.
Installation and User Manual ADPRO FastTrace-R by Xtralis 4.3.6 Communications The Communications menu provides configuration settings for the Ethernet and two serial communication ports. Figure 63: Communications Menu Ethernet Properties A direct connection to a 10BaseT or 100BaseTX Ethernet network can be made via the Ethernet Port. To change this address, the Subnet Mask or Default Gateway address, click the Configure button.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 64: Ethernet Settings IP Address for this Unit Factory Default 192.168.1.1 The IP Address is used to identify the FastTrace-R device as a TCP/IP network node. Each ADPRO Transmitter monitored from the same installation of VideoCentral requires a unique IP (Internet Protocol) address. The address is divided into four parts separated by a (.), each part with a decimal range value from 0 to 255.
Installation and User Manual ADPRO FastTrace-R by Xtralis Subnet Mask Factory Default 255.255.255.0 The Subnet Mask is used in conjunction with the IP Address to determine whether the destination node is located on a local network segment or on a remote network. Each logical IP Address has two parts: the NETWORK ID and the HOST ID. The Network ID identifies all hosts that are on the same physical network and the Host ID identifies a specific host on the network.
ADPRO FastTrace-R by Xtralis Installation and User Manual Serial Communication Properties There are two Serial Communication Ports for analogue telephone line or digital line connection for communications with VideoCentral. Modems are used for analogue line (PSTN) connections and terminal adaptors (TA) for digital lines (ISDN). The COMMS 1 port is fitted with a 25-pin D male connector. The COMMS 2 port is a 9-pin D male (refer to Table 3).
Installation and User Manual ADPRO FastTrace-R by Xtralis Modem/TA Model Options: Model List, Direct Connect Select the model of the modem or terminal adapter (TA) connected to the particular COMMS port. Refer to the device’s user manual to assist with setting the correct configuration. Use the Direct Connect option when the FastTrace-R is connected directly to a PC running the VideoCentral software.
ADPRO FastTrace-R by Xtralis Installation and User Manual Initialisation String This option is used to enter additional Hayes AT commands (in ASCII format) that may be required to configure a modem or Hayes compatible RS232 terminal adaptor to initiate (or activate) a particular product feature or setting. Refer to the User Manual of the particular device to obtain the required Hayes AT commands.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 66: Advanced Serial Communications Local IP Address Factory Default: 192.168.254.1 Sets the Local IP Address assigned to FastTrace-R’s COMMS port. This address is used by the PPP messaging software and is NOT the same as the Ethernet Properties setting or of any other device on the network. When multiple FastTrace-R units are to be accessed from a single VideoCentral system, each FastTrace-R unit MUST have a unique Local IP Address (ie.
ADPRO FastTrace-R by Xtralis Installation and User Manual PPP Password Option: 20 characters maximum. The Password that will be provided by PPP when negotiating a serial IP connection. It is only required when PAP is enabled. Note: The PPP Password is a function of the modem or TA and will also need to be set in the device. Nominal Data Rate (bits/sec) Options: 8 kbps, 16 kbps, 32 kbps, 64 kbps, 128 kbps, Auto Detect.
Installation and User Manual ADPRO FastTrace-R by Xtralis Base Port Number Options: Range is 2049 to 65536 Factory Default 15000 The default value = 15000 and should not be changed unless a conflict occurs due to a network connection of other third-party equipment. Caution: If the Base Port Number is changed, then all FastTrace-R units and VideoCentral must be changed to the same value. Failure to do this on all communicating systems will result in communications failure.
ADPRO FastTrace-R by Xtralis Installation and User Manual 4.3.7 Connected Equipment The Connected Equipment menu provides a number of sub-menus to configure the settings that the FastTrace-R will use when interacting with external equipment such as video cameras, microphones/speakers, alarm inputs and control output devices as well as the local monitor and alarm relay contacts.
Installation and User Manual ADPRO FastTrace-R by Xtralis PTZ Settings Serial Options: 360vision, Amux IEC, Baxall ZMX, Baxall ZTX, Baxall ZTX7, BBV, Burle, COHU, Conway, CS Lilin, Dennard 2050, Diamond, Digital Sprite, Elbex, Ernitec, GPS, Grundig, Harris, JVC, Kalatel CyberDome, Kalatel KTD 12x, Mark Mercer, Molynx, Pacom 2018, Panasonic (Conventional), Panasonic (New), Pelco Coaxitron 4800_8_E_1, Pelco_D_2400_8_N_1, Pelco_D_4800_8_N_1, Pelco P 4800_8_N_1, Pelco P 9600_8_N_1, Philips, Samsung (Lens onl
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 69: Cameras Menu The status of a Channel is shown by a small icon to the left of the Channel number. • • • A Channel is free when the ‘empty’ icon is shown next to the number. The Connect button is used to set the status of a channel and enable the video for recording and viewing. When enabled, other details about this camera can be modified.
Installation and User Manual ADPRO FastTrace-R by Xtralis General Tab Figure 70: Camera Settings - General Tab Camera Name Option: 16 characters maximum. Type the name to be associated with this camera. Hint: Try to use names that make the camera location and the channel number to which it is connected, easily identifiable. For example, CAM07 LIFT LOBBY, REAR DOOR CH15 or CH09 ATM#3 EAST.
ADPRO FastTrace-R by Xtralis Installation and User Manual To help configure the Activity Detection feature, the sensitivity to movement and the amount of time that movement occurs can be programmed. This is done by selecting the Activity Detection tab. PTZ Settings This Camera has a PTZ station. Options: Yes, No Default: No Set the checkbox when this channel is connected to a camera with PTZ (Pan/Tilt/Zoom). The type of PTZ equipment is set in the PTZ Settings option (refer to PTZ Settings).
Installation and User Manual ADPRO FastTrace-R by Xtralis If the Non-Interruptible option is selected, the following dialog box is displayed to warn the user of the potential to cause events to be queued and add delays in capturing event images. Figure 72: Alarm Preset Warning Preset Positioning Time Options: 0, 0.1, 0.2, 0.3, 0.4, 0.
ADPRO FastTrace-R by Xtralis Installation and User Manual Activity Detection Tab Figure 73: Camera Settings - Activity Detection Tab Sensitivity Options: Very Low, Low, Medium, High, Very High Default: Medium Set the required sensitivity of the system. The Sensitivity setting defines a cross section of a target objects size and speed required to trigger an Activity event.
Installation and User Manual ADPRO FastTrace-R by Xtralis Cells are active (i.e. will be able to generate events) when they are highlighted and inactive when the highlight is removed. Options available are: • • • Set All - Places the maximum number of detection zones over the video image. All zones are active. The maximum number of zones for PAL systems is 396 zones (22 wide x 18 high), NTSC systems have 330 zones (22 wide by 15 high). Clear All - Removes all currently assigned zones.
ADPRO FastTrace-R by Xtralis Installation and User Manual 4.3.9 Monitor A local monitor can be connected to the FastTrace-R and used to display a number of camera views in a sequence. Figure 75: Monitor Menu Monitor Settings Set the Local Monitor Connected checkbox if a sequence monitor is to be used. Click the Configure button to setup the sequence. Sequence List The list defines the sequence (order) in which camera images are presented on the monitor.
Installation and User Manual Note: ADPRO FastTrace-R by Xtralis A Transaction Device Software License must be purchased to enable transaction device functionality. Licensing instructions are provided with the purchase of a licence (refer to Licensing). A Transaction Device (for example an ATM or EPOS terminal) can be connected to the FastTrace-R via one of the GP Serial ports or Ethernet port. Up to sixteen transaction devices can be configured.
ADPRO FastTrace-R by Xtralis Installation and User Manual The Connection Port drop down list displays the Data Port that is currently allocated in the FastTrace-R system. Select the Configure … button and the following dialog is displayed.
Installation and User Manual ADPRO FastTrace-R by Xtralis 4.3.12 Alarm Inputs The Alarm Inputs option defines a number of parameters about the type and operation of the alarm inputs connected to the FastTrace-R. The number of alarm inputs available will depend on the FastTrace-R Model number. Select the Alarm Input number from the displayed list. The status of an Alarm Input is shown by a small icon to the left of the channel number.
ADPRO FastTrace-R by Xtralis Installation and User Manual Alarm Input Type Options: Normally Open (N/O), Normally Closed (N/C), N/O SEOL, N/C SEOL, N/O DEOL, N/C DEOL Default: Normally Open The FastTrace-R can be programmed to trigger a recording event when the contacts associated with a channel change state.
Installation and User Manual ADPRO FastTrace-R by Xtralis Select the Presidium Input number from the displayed list. The status of an Presidium Input is shown by a small icon to the left of the channel number. • A Presidium Input is unallocated when no name is shown next to the number. Figure 80: Unallocated Icon • The Connect button is used to enable an Alarm Input. A green tick is shown and details can be modified.
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 82: Presidium Input Settings Presidium Input Name Option: 16 characters maximum. Enter the name to be associated with this Presidium Input. Presidium Input Camera View Style Factory Default: Live Cannot be changed for FastTrace-R operation. 4.3.14 Control Outputs The Control Outputs option defines a number of parameters about the type and operation of the output circuits connected to the FastTrace-R.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 83: Control Output Settings Menu Control Output Settings When the Configure button is used, the following settings can be made. Control Output Name Option: 16 characters maximum. Enter the 16 character name to associate with this output. The name can be displayed when viewing video from a camera input associated with this control output.
ADPRO FastTrace-R by Xtralis Installation and User Manual Defines the operational state of the control output after a user has disconnected from the FastTrace-R. • • the Reset option returns the output to the condition defined by the Default State. the Latch option causes the control output to remain in its current (operated) condition. 4.3.15 Audio The Audio menu configures the FastTrace-R audio channel features.
Installation and User Manual ADPRO FastTrace-R by Xtralis Select the type of audio input device connected to the FastTrace-R unit. Refer to Audio for details of the hardware connector. Note that only one audio input type can be used, i.e. multiple audio inputs cannot be used simultaneously. Microphone Gain Operation Options: AGC Enabled, AGC Disabled Default: AGC Enabled Select either AGC Enabled (Automatic Gain Control) or AGC Disabled.
ADPRO FastTrace-R by Xtralis Installation and User Manual 4.3.17 Operational Behaviour The Operational Behaviour section and settings defines how the system operates overall and how different elements of the system relate, such as alarm inputs to camera views etc. In the main Operational Behaviour screen, operators can select how long different types of images are retained for before being erased from the hard-disk storage.
Installation and User Manual ADPRO FastTrace-R by Xtralis Event (Recording Retention Time) Range: 1 day more than the Normal Retention time (mentioned above) up to 1000 Default: 60 days Event Recording Retention Time sets the maximum number of days that the FastTrace-R will attempt to store images that have been recorded as a result of an (alarm) event. Once the Event time has expired, the disk space will be reallocated for new images.
ADPRO FastTrace-R by Xtralis Installation and User Manual 4.3.18 Operational Modes Figure 86: Operational Modes Menu Up to four different modes can be programmed into the system. Numerous different operational characteristics can be changed within the different modes such as: • • • Rate and Quality of images being recorded for individual cameras. Event triggers associated with cameras. How audio is recorded.
Installation and User Manual ADPRO FastTrace-R by Xtralis Use the Selection Method drop-down box to determine how the modes will be changed (either via an input change or by day / time calendar selection) and press the Configure… button to define the operation. The Use External Input to Change Modes option is used to configure switching between two modes via the use of the Mode Select Input on the rear panel of the unit (Pin 9 of the General I/ O connector).
ADPRO FastTrace-R by Xtralis Installation and User Manual Note that this calendar uses days and not dates, therefore it is not possible to set specific operations for particular dates such as Christmas or New Year. Highlight a block within the calendar (this can spread across days as well as times) to be changed by placing the mouse pointer within the calendar, holding down the left mouse button and then dragging the pointer.
Installation and User Manual ADPRO FastTrace-R by Xtralis 4.3.20 Camera Behaviour Figure 90: Camera Behaviour Menu For each camera, the operation for each of the modes needs to be defined (i.e. up to four lots of settings for each camera). For each Mode / Camera combination, there are three lots of settings that require configuration: Video Capture: Defines the rules for recording the currently selected camera during the currently selected mode.
ADPRO FastTrace-R by Xtralis Installation and User Manual Video Capture (tab) The Video Capture settings define the conditions that need to be met for video to be recorded. This includes the type of recording, the video quality, recording rate and duration of recording. Figure 91: Video Capture Settings Define the Recording Type to be used on this camera during the currently selected Mode. The options are: Do Not Record: This camera will not be recorded at all during this mode of operation.
Installation and User Manual ADPRO FastTrace-R by Xtralis The following table shows the Capture Settings defaults: Table 12: Capture Settings defaults Continuous Event Continuous & Event Normal Pre-Event Event Normal Event Quality (1-7) 4 6 6 4 6 Image Rate (ips) 1 1 5 1 5 Capture Duration (sec) -- 10 30 -- 30 Capture Setting Note: It is recommended that the Quality and Image Rate for Pre-Event are set to the same values as Event, to ensure that pre-event video quality is satis
ADPRO FastTrace-R by Xtralis Installation and User Manual Figure 93: Event Trigger Settings Alarm Logic The Alarm Logic option is used to set up the logical order in which Alarm Inputs are treated before a recording event is declared to be ‘valid’. Up to ten detectors can be associated with any one camera.
Installation and User Manual ADPRO FastTrace-R by Xtralis Select the type of Event Input (either Alarm Input, Activity Detection or Transaction Device) and the Source (the Alarm Input Channel or Video Channel in the case of Activity Detection). Note that any alarm input or activity detection on any camera channel can be used to trigger any camera on the system. The Source for an Event Input is defined by the settings in Connected Equipment / Alarm Inputs (refer to Alarm Inputs).
ADPRO FastTrace-R by Xtralis Installation and User Manual If using the Only When ALL Inputs Occur logic, only the first pre-set on the list will be active. If another Alarm Input is configured for the same PTZ camera, its preset will not be available, and will be displayed with an (N/A) beside the Preset Position. Note: Please refer to PTZ Tech Tips for connection and setup information on the website www.xtralis.com/adpro. Editing a Detector’s Preset To edit a detector’s preset: 1.
Installation and User Manual ADPRO FastTrace-R by Xtralis Activate Control Output When checked, the control output correlating to the camera channel number currently being programmed will be activated for a period as defined in the Alarm Input / Hold Time (refer to Alarm Input Settings) upon full activation of an event. Refer to Control Outputs. Note: If the assigned Control Output number has been specified for Manual Operation, then an error message will be displayed.
ADPRO FastTrace-R by Xtralis Installation and User Manual 4.3.21 Multi-Screen Live Behaviour Figure 99: Multi-Screen Live Behaviour Menu This feature allows the user to view multiple channels in Live Mode simultaneously, in preset configurations. VideoCentral V8.04 or higher and FastTrace-R system software version 1.00 or higher must be installed on the transmitter for Multi-Screen to be available.
Installation and User Manual ADPRO FastTrace-R by Xtralis Guard Tour Settings Guard Tour operation provides a sequence through cameras programmed on the FastTrace-R unit. Depending on the display configuration (single screen or 4, 7, 9, 10, 13, 16 or 20 way split) the system will display all cameras and sequence through on the screen, or sets of cameras will be displayed.
ADPRO FastTrace-R by Xtralis Installation and User Manual The user can create and configure different Multi-Screen profiles according to their preferences. The following screen splits are supported: Single Screen, 4-way, 7-way, 9-way, 10-way, 13-way, 16-way and 20-way. Figure 102: Multi-Screen Settings Buttons Adding a New Profile • • • Click the New Profile button. A new entry ‘New Profile’ will be added to the General Profiles listbox.
Installation and User Manual ADPRO FastTrace-R by Xtralis Adding a Camera from the Cameras Listbox to the Profile Layout Control • • Highlight the camera entry in the Cameras listbox. Click on the [>] button to add the selected camera to the layout. Figure 103: Selectable Multi-Screen Settings As a result of this: • • The selected camera will be removed from the Cameras listbox The selected camera will be added to the Profile Layout.
ADPRO FastTrace-R by Xtralis Installation and User Manual 4.3.22 Entry/Exit Behaviour Figure 104: Entry Exit Behaviour This option is not available in FastTrace-R. Clicking on the Configure button will display the following message.
Installation and User Manual ADPRO FastTrace-R by Xtralis 4.3.23 Maintenance Figure 105: Maintenance Menu The maintenance options available on FastTrace-R are: • • Temperature Monitor Zone Isolate Reminder Temperature Monitor Figure 106: Temperature Management FastTrace-R monitors the internal temperature of the hard disk drives and has the option of generating an alarm if the temperature exceeds an upper limit of 65°C.
ADPRO FastTrace-R by Xtralis Installation and User Manual If High Temperature Management is Enabled When the internal temperature of any disk drive rises above the high temperature threshold, FastTrace-R will initiate an over-temperature condition and generate an alarm. The FastTrace-R fault relay will activate during the over-temperature condition.
Installation and User Manual ADPRO FastTrace-R by Xtralis This will remind the operator that zones have been isolated and that they should be unisolated. To enable this option, tick the check box, then enter an appropriate time to generate the reminder. SitePulse This option is not available in FastTrace-R. Clicking on this option will display an information message.
ADPRO FastTrace-R by Xtralis 5 Installation and User Manual Event Log VideoCentral has the capability to download the contents of a remote FastTrace-R ‘site event log’ for review. This feature is useful when carrying out system diagnostics, or investigating problems associated with events at the site. The event log may be downloaded from Review mode. In Review mode, select the Perform a Search button. Figure 109: Perform a Search Button The Search dialog is displayed. Select the Log tab.
Installation and User Manual 5.1 ADPRO FastTrace-R by Xtralis Save the Event Log The results of an event log search may be saved as follows: 1. Select the Save events or logs button. Figure 111: Save Event or Logs button 2. Select a location to save the text file, enter a filename and select Save. Figure 112: Save As Dialog Note: If the file is loaded in a standard text-editor such as Notepad, it will not appear correctly in columns.
ADPRO FastTrace-R by Xtralis 5.2 Installation and User Manual Severity and Visibility Levels The following table details the Severity assigned to the FastTrace-R event logs.
Installation and User Manual 110 ADPRO FastTrace-R by Xtralis Severity Functional Area Title Informative Motion detection Normal video contrast on camera Informative Settings Default settings used Informative Settings Settings changed by the user Informative Time Daylight savings started Informative Time Daylight savings ended User Action Application system System shutdown requested by user User Action Application system Settings changed by the user User Action Audio Override re
ADPRO FastTrace-R by Xtralis Installation and User Manual The following table details the Visibility assigned to the FastTrace-R event logs Table 15: Assigned Visibility of FastTrace-R Event Logs Log Title Visibility System shutdown requested by user Maintainer System is shutting down Maintainer System is starting up Maintainer System is running Maintainer Error reading settings Maintainer Default settings used Maintainer Settings restored from backups Maintainer Daylight saving started U
Installation and User Manual 112 ADPRO FastTrace-R by Xtralis Log Title Visibility Site disarmed by remote user Maintainer Isolation refused Maintainer Isolation applied Maintainer Isolation removed Maintainer Isolation reminder Maintainer PTZ acquired by user User PTZ released User Multi-screen acquired User Multi-screen released User Settings changed by the user User Settings change failed User File updated by user User Data files repaired User Alarm input active User Alar
ADPRO FastTrace-R by Xtralis Installation and User Manual Log Title Visibility Started mode User Finished mode User Control output active User Control output inactive User Alert generated Maintainer Alert sent to user Maintainer Alert acknowledged Maintainer Alert discarded Maintainer Entry delay started User Entry delay finished User Exit delay started User Exit delay finished User No video alert generated Maintainer A No-Video alert was generated.
Installation and User Manual 114 ADPRO FastTrace-R by Xtralis Doc 13972_03
ADPRO FastTrace-R by Xtralis 6 Installation and User Manual FastTrace-R Impounding The FastTrace-R Impound feature is used when the FastTrace-R unit contains potential evidence and it is deemed that the storing and/or exporting of FastTrace-R data using VideoCentral is not sufficient. Installers will normally change the Impound settings of a FastTrace-R at the request of the site owner. Dip Switch 6 must be enabled on the FastTrace-R unit to enable the Impound feature (refer to Configuration Switches).
Installation and User Manual 116 ADPRO FastTrace-R by Xtralis Doc 13972_03
ADPRO FastTrace-R by Xtralis 7 Installation and User Manual Testing the FastTrace-R System 7.1 Installation and Testing Checklist There are a few do's and don'ts on top of basic installation practices that should be followed to ensure a good and trouble free FastTrace-R installation. • Upon unpacking the FastTrace-R ensure that all the required components are there and that you have received the right equipment. • Remember that the FastTrace-R can only process what it is given.
Installation and User Manual ADPRO FastTrace-R by Xtralis because you can dial out does not mean they can dial in. • 118 Check that all cameras are recording as expected by reviewing stored video.
ADPRO FastTrace-R by Xtralis 8 Installation and User Manual Upgrading the FastTrace-R Software The FastTrace-R software can be upgraded via VideoCentral or FT-R Viewer software running on a PC or laptop. The software can be upgraded over any communications network, as long as a connection can be established between the FastTrace-R and PC. The time for the upgrade to occur will vary depending on the communication speed of the link. 8.
Installation and User Manual ADPRO FastTrace-R by Xtralis Figure 116: 'Flying Papers' Pop-up 5. 6. 7. Once the upgrade file has completed downloading, which may take from 30 seconds on a network connection up to 10 minutes on a modem connection, the 'flying papers' will disappear, the FastTrace-R will disconnect and then reboot. Please wait a few minutes for the new software to restart the FastTrace-R system and then reconnect to the unit.
ADPRO FastTrace-R by Xtralis 9 Installation and User Manual Specifications 9.1 FastTrace-R A FastTrace-R system consists of one or more units and a PC running the VideoCentral software. Connection is via a TCP/IP based Ethernet network, dial-up, leased telephone lines or ISDN. Function Description Video inputs Model 5010 = 10 video inputs, Model 5020 = 20 video inputs, 1 volt p/p video input, 75 ohm or high impedance, selectable via menu. Colour / Monochrome Operation Colour or monochrome.
Installation and User Manual ADPRO FastTrace-R by Xtralis Function Description Alarm inputs Model 5010: 20 alarm contact sensing or logic level inputs. Model 5020: 30 alarm contact sensing or logic level inputs. Programmable to trigger an alarm on contact opening or closure. All inputs have impedance >1 K ohm and transient protection >20 KV. Single End-of-Line (SEOL) or Dual End-of-Line (DEOL) tamper detection on each input. Screw terminal connectors. Voltage input less than 0.
ADPRO FastTrace-R by Xtralis Installation and User Manual Function Description Audio Switch Interface Audio In/Out to VM22A or third party Audio Switcher. Bi-directional audio sent simultaneously with the video (full duplex). Bandwidth: 300 Hz to 3.3 kHz. Input impedance: >6 k ohms. Input level: 10 mV to 400 mV RMS (nom) Output impedance: >6 k ohm. Output level: 315 mV (nom) Serial Output for Channel Number sequencing. Open drain outputs (binary coded hex) indicating the currently selected channel.
Installation and User Manual ADPRO FastTrace-R by Xtralis Function Description Supported Serial Telemetry Stations 360vision Amux IEC Baxall ZMX, Baxall ZTX BBV Burle COHU Conway CS-LiLin Dennard 2050 Diamond Elbex Ernitec GPS Grundig Harris JVC Kalatel Cyberdome, Kalatel KTD 12x Mark Mercer Molynx Pacom Panasonic (Conventional), Panasonic (New) Pelco, Pelco Coaxitron, Pelco Spectradome Philips Sensormatic, Sensormatic Controller, Sensormatic Speed Dome VII Siemens Synectics Unidex Vantage Juno VCL Vic
ADPRO FastTrace-R by Xtralis 9.
Installation and User Manual 126 ADPRO FastTrace-R by Xtralis Doc 13972_03