4.3.14 Presidium Inputs
The Presidium Inputs option enables the configuration of video outputs from a Presidium
Intelligent Video System to the ADPRO FastTx video inputs.
Note: At least one Presidium Input must be configured. If there are no inputs configured,
the following Presidium system alarms will not work at the ADPRO FastTx:
- Presidium Operational
- Tamper alert
- Over Temperature
- Communication to Presidium Lost
- Communication to Presidium Resumed
- Presidium Fault
Note: When connecting a ADPRO FastTx to a Presidium, each ADPRO FastTx video
input must be directly connected to a Presidium video output. Hence, if the
Presidium has 20 channels, a 20 channel ADPRO FastTx is required to operate all
20 channels.
Select the Presidium Input number from the displayed list. The status of an Presidium Input is
shown by a small icon to the left of the channel number.
A Presidium Input is unallocated when no name is shown next to the number.
Figure 82: Unallocated Icon
•The Connect button is used to enable an Alarm Input. A green tick is shown and details can
be modified.
To disable the use of an Alarm Input, the Disconnect button is used and a red cross is shown.
For example, set Disconnect if maintenance is being performed in that area or the sensor is
being replaced.