Doc 11949_06 11
3. Double click on the required communications port (COM1 or COM2).
Figure 8: COM Port Settings
4. Select the Port Settings tab and enter the following settings:
- Bits per second = 115,200 bps
- Data bits = 8
- Parity = none
- Stop bits = 1
- Flow control = hardware
5. Ensure the ADPRO FastTx is free-standing with no obstruction to airflow (cooling fan at
rear).
6. Connect the cable between the ADPRO FastTx COMMS 2 port and the PC's serial port.
Installing the Null Modem Driver
If you are using the Null-Modem cable connection method to connect to the ADPRO FastTx, you
must install the Null-Modem driver in Windows. This step is NOT necessary if a Null-Modem
driver has already been installed on the PC, or if you are using an Ethernet connection to
ADPRO FastTx.
To install this driver:
1. Insert the ADPRO ADPRO VideoCentral Lite CD in the CDROM Drive.
2. If necessary enter an Area code in the Dialing Rules tab.
3. Click the Windows Start button and select: Control Panel / Phone and Modem Options.