Note: On a busy ADPRO FastTx unit that is dialing out regularly, it is possible for the
ADPRO FastTx event queue to grow past the maximum size of six events, and for
events such as SitePulse to be discarded. ADPRO VideoCentral does not raise a
SitePulse timeout event if it is receiving events as the ADPRO FastTx unit is
operating correctly. Confusion may occur if a user searches the ADPRO
VideoCentral Database looking for the SitePulse notification events as they may not
find them at regular intervals as expected.
Note: If a SitePulse interval of greater than a day is specified, and the ADPRO FastTx is
rebooted for any reason, then the day which a SitePulse event is sent will also
change.
Note: SitePulse alerts are sent either to the first listed CMS in the dial-out call list, or the
connected CMS at the time of the SitePulse alert. If more than one CMS is
monitoring a site, the connected CMS will receive the SitePulse alerts and the other
would not receive any, which could cause a SitePulse Timeout alert to be
generated.