User manual
ADPRO FastTx by Xtralis Installation and User Manual
Doc 11949_06 89
Alarm Input Type: Select the type of alarm input. The types available are the same as for a
normal alarm input: Either Normally Open or Normally Closed (no end of line resistors) or
combinations of Normally Open or Normally Closed with either Single or Dual End Of Line
resistors for Tamper detection (SEOL / DEOL).
Note: The alarm input must not already be configured for use.
Once an alarm input is configured as the Arm/Disarm input, it is no longer available
to be used as a standard alarm input, and the Access/Secure input will cease to
operate.
Table 11: Arm/Disarm Alarm Input States
Indicate the Armed State of the Unit
This setting allows an unused control output to be activated when the unit is armed. This output
could then be linked to a local indicator such as a light, to show the armed state of the unit.
To configure:
Activate a Control Output while the unit is armed (secure): Check this box to enable the
feature.
Control Output: Select an unused control output for the output function from the drop-down list.
The control output will be marked as not-usable in the control output configuration.
Default State: This defines the state of the output when the unit is disarmed, either normally
open or normally closed.
Note: The control output must not already be configured for use. Once a control output is
configured for local indication, it is no longer available to be used as a standard
control output.
Indicate Active Sensor
This setting allows an unused control output to be activated when any configured sensor is
active, i.e. alarm input or activity detection. This alerts the user to any problem prior to arming the
system. This output could then be linked to a local indicator such as a light, to show the local
user if there are any active sensors.
Alarm Input State / Alarm
Input Type Setting
Open Circuit Closed Circuit
Low
Impedance
High
Impedance
Normally Open (NO) Disarmed Armed N/A N/A
Normally Closed (NC) Armed Disarmed N/A N/A
SEOL NO Tamper Alert Armed Disarmed N/A
SEOL NC Armed Tamper Alert Disarmed N/A
DEOL NO Tamper Alert Tamper Alert Armed Disarmed
DEOL NC Tamper Alert Tamper Alert Disarmed Armed