Instruction manual
19
TDCT-Pro Time-Date-Character-Title
RS-232 COMMAND SET APPENDIX C
6. Update Date
Command /Dxx
Description
D(1 byte) Date
xx(2 bytes) 01-31
Example Update Date = 5
/D05
/ 0x2F
D 0x44
0 0x30
5 0x35
Master Reset
If you wish to set the unit back to the original factory defaults you can do this by
a Master Reset.
Press and hold the “UP” & “DOWN” & “SET” buttons and then press and re-
lease the “RESET” button. Then release the “Up”, “Down” & “Set buttons. You
will see the copyright and release notice on-screen.
Warning: Doing this will erase all your programming setups !!!
MASTER RESET APPENDIX D