Instruction manual

70
5. PROGRAMMING
VSI-Pro Max POS / Cash Register Interface
Click the Tab “Remote” and you will see the following Menu.
Click on “Set Comport”. If the VSI-Pro Max is in the “Baudrate Detection” Mode then you can set any baud rate and the
VSI-Pro Max will self configure. However if the VSI-Pro Max is already set to a baud rate you must select the exact baud
rate and communication configuration in the VSI-Pro Max for connection to occur. If the unit does not display “Con-
nected” then you have either entered the wrong baud rate or communication settings or a cable problem or the VSI-Pro
Max not powered.
Once connected then click “Remote” and will display “Accessed” or will go back to “No Access” if the baud rate or cable
connection is not proper and will also go back to “Not Connected” so you can reset the communication settings. It might
take 2 or 3 tries to determine the proper auto baud rate.
Once you have “Access” then you can do any function on this menu screen. “Upload” data which reads the current
settings of the VSI-Pro into the PC. “Download” which sends the PC settings to the VSI-Pro. “Set Time” can set a new
time or PC sync time to the VSI-Pro. “Load History” reads the History File of Exceptions from the VSI-Pro and saves as
a text file on the PC.
Note: If the cable is disconnected, VSI-Pro Max reset or powered down, PC program closed, the PC and/or the VSI-Pro
Max has a 30 second timeout and will reset itself for normal operation so wait this time and start again.
Figure 185: Remote Menu