Instruction manual
61
PORT 1 or PORT 2 TEST
Sending and receiving data performance can be analyzed under the PORT 1 TEST or PORT 2 TEST sub-menu. Press the
“Up” or “Down” button to move the cursor to “PORT 1 TEST” and press “Set”. The following sub-menu will appear:
Figure 168: PORT 1 TEST Sub-Menu
RECEIVE [ RX ] TEST
The purpose of this test is to determine that if VSI-Pro Max is receiving the data or not. Press the “Up” or “Down” button
to move the cursor to “RECEIVE [ RX ] TEST”. The following display will appear (example only):
Receiving data will be appear in three sperate lines, scrolling from right to left. The first line is the actual ASCII data
coming from the register while last two lines are HEX conversion of ASCII data. If you do not receive any data, check
the connections between VSI-Pro Max and Register or any additional interfacing device.
Press “Set” to return to the previous menu.
Figure 169: RECEIVE [ RX ] TEST Display
RX BAUDRATE : AUTO
TX BAUDRATE : 2400
PARITY : NONE
DATA BIT : 8
HANDSHAKING : OFF
RECEIVING :
BAUDRATE DETECTION..
VSI-Pro Max POS / Cash Register Interface
5.9 TEST/DEMO MODE
The TEST/DEMO MODE provides you with several ways to test the VSI-Pro Max and demonstrate its capabilities as a
cash register interface. Press the “Up” or “Down” button to move the cursor to “TEST/DEMO MODE” and press “Set”.
The following sub-menu will appear:
Figure 167: TEST/DEMO MODE Sub-Menu
VIDEO LOSS
Choices: Manual, 1s, 2s, 3s, 4s, 5s, 10s, 20s, 30s, 1M
Video Loss allows the VSI-Pro Max to generate an alarm condition when low or lost video occurs. When set for manual
the alarm follows the state of the video loss, when set for 1s-1M this means the video must be lost continuously for that
period of time before an alarm is triggered. The alarm mode is a timed mode so once the video loss alarm is triggered the
alarm time out must expire and get another video loss to retrigger the alarm. Video Loss is “OR” with the Alarm Trigger
so if either one occurs will trigger the appropriate alarm for all the setups for that Alarm number.
RECEIVE [ RX ] TEST
TRANSMIT [ TX ] TEST
RX/TX TEST
BAUD RATE SCAN
EXIT
PORT 1 TEST
PORT 2 TEST
DATA CAPTURE
REGISTER DEMO
VERSION ID
EXIT
5. PROGRAMMING
ALARM TYPE DWELL or TIMED
When set for DWELL Mode the alarm timeout is retriggered every time a new alarm comes in within the dwell period. If
set for TIMED mode the alarm is triggered once and when the time out expires the alarm must reset and retrigger to start
the alarm time out again.
NOTE
In the below tests, you can stop the scrolling data
by holding down either “Up” or “Down” button.