Instruction manual
46
5. PROGRAMMING
VSI-Pro Max POS / Cash Register Interface
NETWORK PROGRAM
The “Network Program” selects and allows you to program the settings of the slave devices.The Sub-Menu of Network
Program can be accessed when the TYPE sub-menu in the NETWORK SETTINGS menu is set to MASTER.
NOTE: You can not change the Network Protocol or Address of any slave from this menu or the units will stop commu-
nicating. If you wish to change these settings you must do by independently by the OSD programming or connecting the
PC Programming software to each device. The default Network Protocol is RegCom 9.6K so all must be the same if you
do change any.
You will be able to change the Network Protocol and address of the VSI-Pro Max Master so if you do and it is not
the same as all the slaves then will not be able to communicate to any slaves. If you add any additional device of an AVE
product via the RS-485 network they also must be the same protocol and address unique.
While accessing the programming menu of any slave, all the other slaves will stop transferring transaction data
to the Master and will be buffering any incoming data in the slave memory. Upon exit from the programming mode the
slaves will then send all the buffered data to the Master. Therefore you should avoid doing remote programming during
high transaction traffic times for will delay the display of the data over the video so will not correspond to live transactions.
If you set the first channel to have Hydra or Master Output to the DVR using the VSI-ADD protocol you must reset this
via the on-screen menu back to default via the on-screen menu to use the PC Programming software for all devices
To access the NETWORK PROGRAM sub-menu, press the “Up” or “Down” button to move the cursor to “NETWORK
PROGRAM” and press “Set”. The following menu will appear:
ADDRESS ID
Choices: N/A,1,2,3,4,5,...,16
This selects the channel that you want to program. To select the Address ID, press the “Up” or “Down” button to move the
cursor to “ADDRESS ID” and press “Set”. The cursor will start flashing. Then press the “Up” or “Down” button to cycle
through the values and press “Set” when the desired address is displayed.
Figure 152: Network Program Sub-Menu
ADDRESS ID 1
SELECT CHANNEL
EXIT
SELECT CHANNEL
This selects when you want to access the “Main Programming Menu of a slave device” which selected from “ADDRESS
ID” sub-menu. The SELECT CHANNEL can operate when the RS-485 network protocol of master is identical with RS-485
network protocol of slave device that selected from ADDRESS ID sub-menu.
To access the “Main Programming Menu of a slave device”, press the “Up” or “Down” button to move the cursor to
“SELECT CHANNEL” and press “Set”. The following menu will appear which is the Main Menu of the slave device.
Figure 153: Main Programming Menu of Slave VSI-Pro Max via a VSI-Pro Max as Master
Using the front panel buttons of the VSI-Pro Max Master you will navigate the menu of the Slave VSI-Pro Maxt identically
as if you were navigating the Master unit.
REGISTER SELECT
SCREEN SETUP
TEXT DISPLAY
COMMUNICATION
EXCEPTION REPORT
ALARM OUTPUTS
TEST/DEMO MODE
DOWNLOAD/UPLOAD SETUP
MASTER RESET
HELP