Instruction manual

81
VSI-Pro VIDEO SERIAL INTERFACE
To enable the Time Sync function. Access the Main Menu, press the “Up” or “Down” button to move the cursor to
“SCREEN SETUP” and press “Set” then move the cursor to “CLOCK” and press “Set” then move the cursor to “T/D
LOCKING” and press “Set”. and then move the cursor to “TIME SYNC” and press “Set”. The cursor will start flashing.
Press the “Up” or “Down” button to change the value is “ON” and press “Set” then back to the Main Menu. Press the “Up”
or “Down” button to move the cursor to “EXCEPTION REPORT” and press “Set” then move the cursor to “EXCEPTION
HISTORY” and press “Set” and then move the cursor to “DVR SELECTION” and press “Set”. Press the “Up” or “Down”
button to move the cursor to “MVDR3000/5000” and press “Set”. The MVDR3000/5000 sub-menu will appear:
Press the “Up” or “Down” button to move the cursor to “DEST ID” and press “Set”. The cursor will start flashing. Press the
“Up” or “Down” button to change the value and press “Set” when the value of the “DEST ID” as identical with the “COMM
ID” or “UNIT ID”of the DVR, then move the cursor to “SRC ID” and press “Set”. The cursor will start flashing. Press the
“Up” or “Down” button to change the value of “SRC ID” as 32 and press “Set” then back to the Main Menu.
Time Sync and Alarm Sync function within VSI-Pro RS-485 Network and MVDR3000/5000
Figure 148: MVDR3000/MVDR5000 Sub-Menu
RS-485 Network of VSI-Pro with Alarm Sync Function for MVDR3000/5000
If the alarm of VSI-Pro within the VSI-Pro RS485 network is triggered and the Alarm Sync function is enabled. The VSI-
Pro will send command to DVR to start recording immediately.
To enable the Alarm Sync function. Access the Main Menu, press the “Up” or “Down” button to move the cursor to
“ALARM OUTPUTS” and press “Set” then move the cursor to “ALARM SYNC” and press “Set”. the cursor will start
flashing. Press the “Up” or “Down” button to change the value is “ON” and press “Set” then back to Main Menu. Press the
“Up” or “Down” button to move the cursor to “EXCEPTION REPORT” and press “Set” then move the cursor to “EXCEPTION
HISTORY” and press “Set” and then move the cursor to “DVR SELECTION” and press “Set”. Press the “Up” or “Down”
button to move the cursor to “MVDR3000/5000” and press “Set”. The MVDR3000/5000 sub-menu will appear:
DEST ID 1
SRC ID 32
EXIT
RS-485 Network of VSI-Pro with Time Sync Function for MVDR3000/5000
If the transaction which include time and date is sent out from the Cash Register and received by the VSI-Pro via
Vnetworker has occurred and The Time Sync function is enabled. The time and date of a DVR will synchronize with the
time and date of a VSI-Pro in RS485 network.
TIME SYNC and ALARM SYNC APPENDIX L
Figure 147: Connection Diagram of VSI-Pro RS-485 Network with MVDR3000/5000
Note: Setting the DIP switch of Hydra
for support this feature can found in the
Hydra manual.
RS485
RS232
VSI-Pro
Cash Register
MVDR3000 / MVDR5000
RS232
RS232
Hydra Ver 800/801 or VSI-Pro Max
Master
VNETWORKER
V600R4