Instruction manual
73
Figure 127: Time / Date Setup Menu
Figure 128: Remote Keyboard Window
VSI-Pro VIDEO SERIAL INTERFACE
RS-485 VNETWORKER APPENDIX E
Transaction Windows
Figure 126: Transaction Windows
Files:
C:\Logfiles directory contains all the files with the name
extension Address1.txt, Address2.txt, etc
corresponding to the address of the Networker/
Vnetworker. These files are updated continuously. If
you copy and then delete the file, a new log file will be
created with the same number as new data is recieved.
Viewing the files is updated every 2 seconds.
Setting Time & Date
This window allows you to read or set the Time/Date of any VSI-Pro. First
select the ID or address of the VSI-Pro. Click “Read Clock” for the current
T/D set in that particular VSI-Pro. If you wish to change the T/D then set
the T/D in the selections provided and click “Set Clock”.
Remote Keyboard
Selection of the remote keyboard allows you to access any of the Vnetworkers on the network which controls the VSI-
Pro into the programming mode. During programming time all data from the cash register to the VSI-Pro will be lost for
disconnected from the VSI-Pro until released from programming.
Upon accessing a valid address of a Vnetworker and connected to a VSI-Pro Ver. 13.XX Rel. 12 or higher the following
screen will be presented. The menu presented is identical to the local programming mode of the VSI-Pro. Clicking the
Up, Down, Enter and Reset buttons on the software is exactly like pressing the front panel buttons of the VSI-Pro.
Special buttons like Erase Character and Save String Input allow for the combination buttons used in the local VSI-Pro
programming mode. Programming features like OSD display position will be slightly different than the local mode since
no video feedback is presented in this programming mode.
NOTE: When in the VSI-Pro Programming mode the Cash Register or RS-232 device is disconnected from the VSI-Pro.
Therefore any data sent by the cash register while in the programming mode will be lost.