Instruction manual

72
Vnetworker PC Software Ver. 2.3
The basic software of the Vnetworker is a super set of the Networker software. The additional features allow the user to
interactively program the VSI-Pro.
Figure 124: Vnetworker PC Software Main Menu
Figure 123: Select the ComPort Menu
The Yellow Led is indicated when a Vnetworker/Networker is detected.
The Red Led is indicated when no Vnetworker/Networker at that address.
The Green Led is indicated when receiving data.
The Blue Led is indicated when the alarm has occurred.
Figure 125: View Status Menu
From this pulldown menu you can select the ComPort and baudrate. Select 32
Address when using less than 32 registers and select 64 if using more than 32
registers.The default baudrate is 19.2K for the Vnetworker Protocol. The ComPort
is dependent on your computer. The Vnetworker PC Software Main Menu will
appear:
View Status
Select the Control Menu then select View Status drop down list. The View
Status windows will appear:
VSI-Pro VIDEO SERIAL INTERFACE
APPENDIX E RS-485 VNETWORKER
Note: Setting the DIP switch of Hydra
for support the Vnetworker PC software
can found in the Hydra manual.
Vnetworker
V600R4
VSI-Pro
Cash Register
VSI-Pro Vnetworker
(DB9M) (DB9F)
2 ----------------------- 2
3 ----------------------- 3
5 ----------------------- 5
7 ----------------------- 7
Vnetworker Cash Register
(DB9M)
2 ------------------ Tx
5 ------------------ Gnd
RS485
Networker
V601R4
VSI-Pro Networker
(DB9M) (DB9F)
3 -------------------- 2
5 -------------------- 5
7 -------------------- 7
VSI-Pro
VSI-Pro Cash
(DB9M) Register
2 ----------------- Tx
5 ----------------- Gnd
Video Output
Video Input
Video Input
Video Output
Cash Register
OR
RS-232
RS485 to RS232
Converter
AVE USB232
RS-485 to USB Converter
USB
Figure 122: Vnetworker and Networker Connection Diagram