Instruction manual
16
PROGRAMMING
5.2 MAIN PROGRAMMING MENU
Following is a detailed description of the menu selections and the programming capabilities of the VSI-Pro.
Figure 9 : VSI-Pro Main-Menu
REGISTER SELECT
SCREEN SETUP
TEXT DISPLAY
COMMUNICATION
EXCEPTION REPORT
ALARM OUTPUTS
TEST/DEMO MODE
DOWNLOAD/UPLOAD SETUP
HELP
5.1 GETTING STARTED
To access the main-menu of the VSI-Pro, simultaneously hold down the “Down” & “Up” buttons and press and
release the “Reset” button and then release the “Down” & “Up” buttons. This will take you to the main programming
menu. To navigate through this menu, simply use the “Down” and “Up” buttons to position the cursor in front of the
desired function, then press “Set” to access that function.
If you have difficulty entering the main-menu, try the following procedure exactly. With your left thumb, lightly press
and hold in the two buttons to the left (Up & Down). While holding down these buttons, press and release the “Reset”
button with your right thumb. Then release the other buttons.
5.3 REGISTER SELECT
To select a specific register, press the “Up” or “Down” button to move the cursor to “REGISTER SELECT“ and press “Set”.
The REGISTER SELECT menu will bring up a sub-menu consisting of registers shown in Figure 10-A. You can go to the
next or previous page by placing the cursor in front of “NEXT” or “PREVIOUS“ and then pressing “Set”. To select the
desired register, press the “Up” or “Down” button to move the cursor to that register and press “Set”. After selecting the
register, exit out of the REGISTER SELECT menu by pressing the “Up” or “Down” button to move the cursor to “EXIT” and
then pressing “Set”. In the main-menu, press “Reset” to activate the programing for that specific register. REGISTER
SELECT automatically formats the VSI-Pro to match your register’s communication settings. However, if you need to
change these settings, you can do so through the COMMUNICATION menu described later in this manual.
VSI-Pro VIDEO SERIAL INTERFACE
NOTE
If a sub-menu has an “EXIT” selection, always go there and press "Set". Pressing
"Reset" at the main-menu exits you from the programming mode.
NOTE
Whenever you select a register in this menu, certain programming features are reset to
the default settings. Always set the register selection first, get the data on-screen, then
proceed with additional programming.