Service manual

2-24 Installation: Electrical Connections
Table 2-7. J5 System Connector, Row B Pins
Pin # Pin Assignment
Input/
Output
To/From Signal Characteristics
1 Reserved O J1-B32, J2-B32
2 Reserved O J1-B31, J2-B31
3 Carrier Operated Relay (Common) O J1-B30, J2-B30 Common Relay Contact
4 Carrier Detect Switch O J1-B29, J2-B29, J3-B24 TTL output, active high
5 Reserved I J1-B28, J2-B28
6 Reserved I J1-B27, J2-B27
7 Reserved I J1-B26, J2-B26
8 Reserved I J3-B25
9 Reserved I/O J1-B24, J2-B24
10 N/C N/C
11 Reserved I/O J1-B22, J2-B22
12 Reserved I/O J1-B23, J2-B23
13 Reserved N/C
14 Reserved I J1-B19, J2-B19, J3-B19, J7-14
15 GND Station ground
16 N/C
17 N/C
18 Accessory 14.2 VDC O P8 pins 3, 4 (through F2) +14.2 VDC
19 GND Station ground
20 5 VDC O P8 pins 7, 8 +5.1 ± 0.25 VDC
21 Reserved O J1-B12
22 N/C
23 N/C
24 N/C
25 N/C