Service manual
2-18 Installation: Electrical Connections
2.3.1 Power Supply Connections
2.3.1.1 AC Input Power Connection
Each base station/repeater is shipped with an 2.5 m (8 ft) 3-conductor line cord. Figure 2-10 shows
the AC line cord connector. Insert the plug into an appropriate grounded outlet.
The North American line cord is equipped with a NEMA 5–15 plug, intended for 110/120 VAC
operation. The optional European line cord (X189AA) is equipped with a “Schuko” style CEE VII (7)
plug, intended for 220/240 VAC operation. See Table 2-4 for plugs for different countries.
If an alternate line cord is required, obtain a line cord employing “HAR” flexible cord with fittings
approved by the safety testing agency in the end-use country.
2.3.1.2 DC Input Power Connection
For DC-only operation, the DC source power is connected to the base station/repeater through the
battery backup connector shown in Figure 2-10. The operation is also described in
“Battery Connection” on page 2-19. The DC source must be located in the same building as the base
station/repeater, and it must meet the requirements of a SELV circuit.
The DC power cable (CA01520AA) can be used for the base station/repeater.
Do not apply AC power to the base station/repeater at this time. Make sure that
the circuit breaker associated with the AC outlet is turned to OFF.
The AC socket-outlet must be installed near the equipment and must be easily
accessible.
Table 2-4. Plugs for Different Countries
Location Option Number
Europe X189AA
U.K. X162AD
Australia X191AD
Ensure that the appropriate voltage is connected with a nominal 28.6 VDC
(21.0 to 32.0 VDC).