Drum Motor
Installation
Warning notices concerning the electrical installation
Electrical connection of the Drum Motor
Connecting Drum Motor -
Cable option
¾ Ensure that the motor is connected to the correct voltage supply according to
the motor data label.
¾ Ensure that a suitable earth connection is made to the Drum Motor cable lead
colored green/yellow.
¾ Connect the Drum Motor according to the connection diagrams (see chapter
"Connection Diagrams" of the respective series)
Connecting Drum Motor -
Terminal Box option
¾ Remove the cover plate of the Terminal Box.
¾ Ensure that the motor is connected to the correct supply according to the
motor data label.
¾ Ensure that a suitable earth connection is made to the Drum Motor Terminal
Box earth connector.
¾ Connect the Drum Motor according to the connection diagrams (see chapter
"Connection Diagrams" of the respective series).
¾ Reinstall the cover plate.
Risk of electric shock
¾ Ensure that the electrical installation is only be
executed by qualified and authorized persons.
¾ Disconnect the power supply before installing, removing
or rewiring the Drum Motor.
¾ Always refer to the connection instructions and ensure
that the motor power and control circuits are connected
properly.
Risk of damage to the Drum Motor
¾ Do not apply DC supply to an AC Drum Motor or AC
supply to a DC Drum Motor as this will cause
irreparable damage.
¾ Do not connect D-series Drum Motors directly to the
mains supply. Connect the D-series Drum Motors only
to suitable VFD or servo drive controllers.
WARNING
Connection Diagrams i-series: see page 34
Connection Diagrams S-series: see page 50
Connection Diagrams E-series: see page 59
Connection Diagrams D-series: see page 68
Damage to the internal wiring due to modification of
Terminal Box
¾ Do not dismantle, reassemble or modify the Terminal
Box in any way.