User manual

89
Version 2.4 (10/2011) en
Original instructions
Drum Motor
Installation
¾ If necessary, fix a retaining plate over the mounting bracket to secure the
Drum Motor's shaft. However ensure that the shaft can move axially on one
side to allow for thermal expansion.
Hygienic installation
¾ Ensure an open and easy accessible mounting which facilitates cleaning and
inspection.
¾ To fulfill EHEDG recommendations, ensure that there is no metal-to-metal
contact between the motor shaft and the conveyor frame, for example by
using a rubber sealing between shaft and frame. The rubber shall be USDA/
FDA and EC 1935/2004 compliant.
Axial play
Torsion play
1.0 mm
max. 0,4 mm
Hygienic installation