User manual

72
Version 2.4 (10/2011) en
Original instructions
Drum Motor
Options and accessories
Over excitation voltage = 2 x nominal operating voltage, divided t
pick up
by two.
Standard 104 VDC, from stock available
All brakes are suitable for frequent start/stop.
The brake opening and closing response times can vary substantially depending
on:
the type and viscosity of the oil
the level of oil in the drum motor
the ambient temperature
the internal motor working temperature
Brake rectifier for i- and S-series
Using a fast acting rectifier or a phase rectifier will save energy because the
holding voltage is lower than the starting voltage.
AC switching (Terminals 1 and 2 of the
brake rectifier)
slow opening response time
brake voltage approx. 1 V
slow closing response time
DC switching (Terminals 3 and 4 of the
brake rectifier)
fast opening response time
brake voltage approx. 500 V
fast closing response time
Electronic rectifier behavior similary to DC-switching
Note
The usable brake torque is approximately 35% of the above listed torque
according to experience.
Input
voltage
V AC
Brake
voltage
V DC
Starting
voltage
V DC
Holding
voltage
V DC
Type Application Reference
number
115 104 104 52 Fast acting
rectifier
Start/stop applications or
continuos run applications
BC0005
230 207 207 104 Fast acting
rectifier
Start/stop applications or
continuos run applications
BC0005
230 104 104 104 Half wave and
bridge rectifier
Start/stop applications or
continuos run applications
BC0002
230 104 190 52 Phase rectifier Continuos run applications BC0004
400 104 180 104 Multiswitch Start/stop applications or
continuos run applications
BC0010
460 104 180 104 Multiswitch Continuos run applications BC0010
460 207 207 207 Half wave and
bridge rectifier
Start/stop applications or
continuos run applications
BC0003