General technical information
Thermal protector
The thermal control protection switch fitted inside the stator coil is closed under
normal running conditions. If the motor overheats, the switch will open at a preset
temperature (depending on the winding insulation class) before damage to the
motor can occur.
Standard version:
Temperature limiter,
automatically resetting
The switch automatically re-sets when the motor has
cooled down
Unintentional start of the motor
¾ Connect the switch to a suitable relay or contactor to
ensure disconnection of the power supply to the motor
when tripped.
¾ When the switch has tripped, wait until the motor has
cooled down and ensure that no persons are
endangered before restarting the motor.
WARNING
Lifetime: 10 000 cycles
AC
cos = 1 2.5 A 250 VAC
cos = 0.6 1.6 A 250 VAC
DC
1.6 A 24 VDC
1.25 A 48 VDC
Lifetime: 2 000 cycles
AC cos = 1 6.3 A 250 VAC
Back setting temperature 40 K ± 15 K
Resistance < 50 m
Contact bounce time < 1 ms