User manual
9
Version 2.4 (10/2011) en
Original instructions
Drum Motor
General technical information
Technical data
1)
Depending on the ambient temperature, different oil types may be required
(see "List of oil types", page 99). For ambient temperatures under +5 °C anti-
condensation heating is recommended. Under -20 °C special shaft seals and
cable are required.
Product identification
To identify a Drum Motor, the following information is required. You may enter the
values of your Drum Motor in the last column.
Protection classification IP66
Ambient temperature range for normal
applications
1)
+5 °C to +40 °C
Ambient temperature range for low
temperature applications
1)
-25 °C to +15 °C
Ambient temperature range for de-
rated drum motors
1)
+5 °C to +25 °C
Cycle times max. 3 starts/stops per minute
Higher cycle times possible with
variable frequency drive (VFD) or
special design
Installation altitude above sea level max. 1000 m
Information Possible value Own value
Drum Motor label Motor type
Speed in m/s
Serial number
Shell length in mm
No. of poles
Power in kW
Shell (tube)
diameter
e.g.
112.3 ends of drum
113.3 middle of drum
Lagging material e.g.
Rubber
Thickness
Profile