User's Manual

Component Flag Description
monitor wakes up (after start-up
or the last memory check
attempt).
The values are 1800 (0.5 hrs) to
86400 (24 hrs). The default
value is 86400 (24 hrs).
SIP-traffic monitor DOS_PACKET_RATE Determines the maximum
number of packets per second
that is allowed.
SIP_traffic monitor DOS_MAX_LIMIT Specifies how many packets past
DOS_PACKET_RATE the IP
Deskphone can receive before
packets are dropped.
If packets are received at a rate
of DOS_PACKET_RATE +1,
then packets start getting
dropped after the time specified
in DOS_MAX_LIMIT (in
seconds).
SIP-traffic monitor DOS_LOCK_TIME Specifies the amount of time (in
seconds) the IP Deskphone stops
processing packets after
DOS_MAX_LIMIT is reached.
• If DOS_PACKET_RATE is < 1,
other values are ignored and
packets are not dropped.
Logging System LOGSIP_ENABLE Allows the administrator to
enable or disable SIP-logging.
• If the parameter is YES, the
SIP-logging Manager is active
and starts logging SIP incoming
and outgoing packages into the
log files in FFS.
• The values are YES and NO.
The default value is NO (the
manager is not active and the
IP Deskphone does not log in
SIP incoming and outgoing
packages.
Diagnostics and troubleshooting
354 SIP Software for Avaya 1100 Series IP Deskphones-Administration November 2012