User's Manual
42 Site planning and hardware deployment
2 Scroll down to System
.
3 Dial ***76#.
4 Scroll down to Site Survey.
5 Press OK.
6 Use the handset to detect frame errors and signal strength.
The Frame Error value for the handset is the number of
detected Sync/ACRC errors within the last 100 receiving
frames, for example, 1 second. For proper deployment,
ensure the Frame Error value does not exceed 4. An Radio
Signal Strength Indication (RSSI) value of –80 dBm to
–85 dBm is used to indicate the cell boundary. For more
information, see “Signal strength and frame errors” (page 22).
--End--
• Subscribe a handset that has de-subscribed in error.
Procedure 2
Re-subscribing a handset
Step Action
1 Long-press the button on the basestation to open the DECT
system.
2 On the handset, navigate to Menu > System > Subscription >
New.
3 Enter the PARK number provided at the bottom of the
basestation.
4 Enter the authorization code (the last four digits of the serial
number at the bottom of the basestation).
--End--
Deployment terms
The following table lists terms associated with deployment.
Table 4
Deployment terms
Term Definition
Estimated number of handsets The average number of handsets expected in a
particular cell.
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 02.02 30 March 2010
Copyright © 2008-2010 Nortel Networks. All Rights Reserved.
.