User's Manual

Basic (simple) SIP DECT configuration with CS 1000 SIP Line Gateway 179
Prompt Response Description
TN L s c u, for
example, 96 0 1
0
where L = virtual superloop, s = shelf,
c = card, u = unit
UXTY SIPL UEXT subtype
DES
aaaa
Designator. Optionally, enter a description.
SIPU
xxxx
SIP DECT user DN
NDID
xxxx
SIP Line Node ID
SCPW
xxxx
password configured in DAP Controller (Procedure 91
“Configuring SIP Settings” (page 165)).
KEY 0 aaa yyyy, for
example,
0 SCR 5001
0 aaa yyyy = Primary UEXT DN:
aaa = MCN, MCR, SCN, or SCR
yyyy = primary DN
1 HOT U yyyy,
for example,
1 HOT U 4425010
1 hot u yyyy = Target DN:
yyyy = User Agent DN prefix (configured for SIP Line)+
subscribed DN on DAP
Configuring CLID
Before configuring CLID, create a CPND block.
You can configure CLID using LD 95.
Table 32
LD 95: Configure CLID
Prompt Response Description
REQ NEW
TYPE NAME
CUST
n
n = customer number
DN xxxx, for example
5001
DN configured at the DAP and UEXT Key 0 at DN.
NAME aaaaaa, for
example
Nick Johns
Handset user name
Enabling message waiting indication
The following configuration in Customer Data Block must be presented to
enable Message Waiting Indication (MWI) for IP DECT handsets.
Package 175 must be enabled on the Call Server for this feature.
You can configure MWI using LD 15.
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 02.02 30 March 2010