178 SIPL configuration
Prompt Response Description
TYPE FTR FTR_DATA
CUST
n
n = customer number
...
PCA ON Enable Personal Call Assistant
...
Configuring Universal Extension
Universal Extension (UEXT) redirects incoming calls to the DAP. Key 0
corresponds with the DN, configured on the DAP. Key 1 HOT U is the
same number with a User agent DN prefix configured for SIP Line.
If you plan to create a Branch Office Configuration, see "Perform
configuration on Call Server" (page 145) .
Use LD 15 to configure station control password length before you
configure the UEXT for SIP Line users.
Table 30
LD 11: Configure station control password length
Prompt Response Description
REQ CHG
TYPE FFC FFC_DATA
CUST
n
n = customer number
SCPL
x
x = the maximum length of the password
Use LD 11 to configure UEXT.
Packages 139, 415, and 417 must be enabled on the Call Server.
If you plan to configure Microsoft Office Communicator for your SIP
DECT handset, you must add the required settings to the UEXT block
(AST 0; CLS T87A). For the changes to take effect, you must save your
configuration using LD 43, and restart your system.
Table 31
LD 11: Add universal extension (UDP)
Prompt Response Description
REQ NEW Add new extension
TYPE UEXT Universal Extension
CUST
n
n = customer number
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 02.02 30 March 2010
Copyright © 2008-2010 Nortel Networks. All Rights Reserved.
.