User's Manual
Data bits 8 Stop Bits 1 Settings > Emulation TTY
DTE cables
These cables are used for system maintenance and diagnostics under Avaya guidance. They
can also be used for connection of RS232 serial terminal adaptor equipment to the control unit.
This cable is a "Straight through DB9 female to DB9 male serial cable."
9-Way RS232 DTE Port Signal PC/Terminal Adaptor
3 Receive data 3
2 Transmit Data 2
7 RTS (Request To Send) 7
8 CTS (Clear To Send) 8
6 DSR (Data Set Ready) 6
5 Ground 5
1 DCD (Data Carrier Detect) 1
4 DTR (Data Terminal Ready) 4
9 RI (Ring Indicator) 9
About erasing the configuration
The following procedures erase the B5800 Branch Gateway configuration stored in the control
unit. This includes both the current configuration being used in RAM memory and the backup
configuration stored in non-volatile memory. Following this, the B5800 Branch Gateway will
restart with a default configuration.
These procedures should be performed from a PC with a fixed IP address, directly connected
to the B5800 Branch Gateway control unit and with the B5800 Branch Gateway system
disconnected from any network. The control unit IP address will default to 192.168.42.1.
Important:
Do not perform any of these processes unless absolutely necessary. The configuration
settings can be returned to the default settings using Manager by selecting File > Advanced
> Erase Configuration command.
DTE port maintenance
Implementing the Avaya B5800 Branch Gateway November 2011 243