User's Manual

Figure 56: Deployment Kit 2 and carrying case
The following information can be used in conjunction with the DeT
eWe User Manual that
accompanies the deployment tool.
1. The two DeTeWe handsets with the kit are subscribed to the basestation and are
numbered 13 and 15. Refer to
Figure 57: Assembled Deployment Kit 2 and DeTeWe
handsets on page 90
to view the assembled basestation and the DeTeWe
handsets.
2. The key on the handset is the Off-Hook key.
3. To enter Site Survey Mode on the handset:
Press Menu
• Scroll to System
• Dial ***76#
• Scroll to Site Survey
• Press OK
4. The FE value for the PP is the number of detected Sync/ACRC errors within the last
100 receiving frames (i.e., 1 sec.). For proper deployment, the FE value must not
exceed 5.
Site planning
88 DMC DECT Fundamentals August 2012
Comments? infodev@avaya.com