User's Manual
DECT on Cabinet system
The Order
Tool allows the first 40 basestations to be phantom powered. When more than 40
basestations are requested, the extra basestations are assumed to be local powered. Power
adapters are provided as follows:
• C4610 AC adapters = (sum of 6-channel and 12-channel basestations) – 80
• Adapters must be purchased separately
DECT on Chassis system
All basestations can be powered from the cabinet power supply
.
DECT on CS 1000E
All basestations can be powered from the Media Gateway power supply
.
Rules with new basestations
With the new basestations, the provisioning rules are relaxed to allow the maximum number
of basestations to be provisioned for each shelf, without the requirements.
Basestation combinations for handsets on a DMC8
Low traffic for a 0.1 Erlang capacity
Table 6: Number of handsets for a 0.1 Erlang capacity on page 44 shows the 6-channel and
12-channel basestation combinations required to support a maximum number of handsets on
a DMC card. The calculations are based on each handset generating 0.1 Erlangs of traffic.
Table 6: Number of handsets for a 0.1 Erlang capacity
Number of 6-
channel base
stations
Number of 12-channel basestations
0 1 2 3 4 5 6 7 8
Engineering guidelines
44 DMC DECT Fundamentals August 2012
Comments? infodev@avaya.com