User's Manual
System Basestation
average line
length
Required number of unoccupied slots
1.7km for every 1 – 6 slots, one slot must be unoccupied
Cabinet 0.5 km for every 1 – 9 slots, one slot must be unoccupied
1.0 km for every 1 – 8 slots, one slot must be unoccupied
1.7km for every 1 – 15 slots, one slot must be unoccupied
Chassis 0.5 km no restrictions
1.0 km no restrictions
1.7km no restrictions
CS 1000E
0.5 km no restrictions
1.0 km no restrictions
1.7km no restrictions
Netprice Order Tool
The Netprice Order
Tool makes certain approximations in provisioning DMC8. This provides
a simplified configuration that meets the needs of most sites.
DECT on Large Systems
The Order
Tool allows the first 80 basestations to be phantom powered. When more than 80
basestations are requested, the extra basestations are assumed to be local powered. Power
adapters are provided as follows:
• C4610 AC adapters = (sum of 6-channel and 12-channel basestations) – 80
• Adapters must be purchased separately
Note:
Because it is not possible to determine how the cards are spread over the two shelves,
it is assumed that there are 80 phantom powered basestations per system.
DMC8 engineering guidelines
DMC DECT Fundamentals August 2012 43