User's Manual

Chapter 8: Changing the DMC8 jumper
setting after DECT system
upgrade to Release 5.0
During the upgrade from CS 1000M Cabinet using Release 4.5 SSC to CS 1000E Cabinet running Release
5.0 equipped with a DECT
system, the DMC TNs listed in the DMC DECT Manager application show up
correctly only by modifying the jumper settings of DMC8.
Changing the DMC8 jumper setting
The following procedure outlines how to change the jumper setting of DMC8 cards.
1.
Complete the upgrade from SSC to CPPM system
2. Disable all DMC8 cards
3. Unplug each DMC8 and change the JUMPER setting of J2
4. Install J2 jumper straps on the DMC8 and the DMC8-Es for the system type. Use
strap A B for IPE shelf, and for IPMG - the CPPM call server with IPMG is considered
a large system