Alarm code Alarm description Maintenance action
The DCT403 alarm must always
come from both the source and
destination DMC8 cards.
DCT404 (DCT404 only displayed in the Alarm
browsers.) One of the following
events occurred:
•
the power was turned on
• the DMC8 was inserted into the
shelf backplane
• a software exception restarted the
DMC8
If this alarm was caused by a
software exception, examine the
alarm browsers for details.
Radio Fixed Part alarm muted
DCT501 Alarms are muted in the RFP window,
however the basestation does not
have any intrinsic alarms.
Use the RFP window to Cancel Mute
Alarms.
Backplane controller unit
DCT601 This alarm is used by Avaya
designers.
Information only, no action needed.
LED status for DMC8/DMC8-E and basestation
The system LED status indicates the functioning of the DMC8/DMC8-E, basestation power
and card subsystem operation.
T
able 47: DMC8/DMC8-E red LED status
Red LED
State
Description Action
On The card is in one of the following states:
1.
not programmed
2. disabled
3. has faults
1. Program the card. See
Resolving a subscription
configuration
mismatch on page 263.
2.
Re-enable the card. Use
LD 32 ENLC l s c.
3. Replace the card. See
Removing and inserting a
DMC8 for maintenance on
page 275
.
LED status for DMC8/DMC8-E and basestation
DMC DECT Fundamentals August 2012 273