User's Manual
Alarm code Alarm description Maintenance action
DCT205 Local bit error rate bad. Perform the DCT202 maintenance
action.
DCT206 Remote receiver signal missing. Perform the DCT202 maintenance
action.
DCT207 Remote loss of receiver slot
synchronization.
Perform the DCT202 maintenance
action.
DCT208 Remote loss of receiver frame
synchronization.
Perform the DCT202 maintenance
action.
DCT209 Remote bit error rate bad. Perform the DCT202 maintenance
action.
DCT210 Synthesizer out of synchronization. Perform the DCT202 maintenance
action.
DCT211 Power amp out of order. Perform the DCT202 maintenance
action.
DCT212 Round-trip delay changed. Perform the DCT202 maintenance
action.
DCT213 RFP synthesizer type changed. Perform the DCT202 maintenance
action.
DCT214 LFC out of synchronization with
BMC.
Disconnect and reinsert the DMC8.
DCT215 Error due to synchronization-port
mutation.
Can affect the interpretation of the
alarm snapshot or alarm browser
applications; however
, the alarm
must clear automatically within 200
seconds.
Faceplate cable alarms
DCT301 No faceplate cable alarm. (DCT301
only displayed in the
Alarm
browsers.)
Information only, no action needed.
DCT302 The DMC8 card is working; however,
there is a loss of faceplate cable
synchronization.
Remove all the DMC8s. Check the
strap setting on the DMC8s. Check
the faceplate cabling. Reinsert all the
DMC8 cards.
If the above procedure does not solve
the problem, try to find which DMC8
card gives the error condition by
inserting the DMC8 cards one at a
time with a minute in between
insertions.
Alarm Code maintenance actions
DMC DECT Fundamentals August 2012 271