User's Manual
Table 43: LD 10 - Convert handset type 500 to DCS
Prompt Response Description
REQ CDCS Convert Digital Cordless Set – always convert from a
non-concentrated to a concentrated system after
software upgrade. Non-concentrated mode is not
supported now
. The conversion routine converts the
500 units to DCS units and moves them from the
actual TN to a virtual TN.
The CDCS conversion routine prints each TN as it is moved, in the following format:
500 TN l s c 00 = DCS TN L S C Index#.
where: L
S C = virtual TN
Example
Index# = default of the unit number of the 500 type set.
Table 44: LD 20 - Print actual DMC8 TN and virtual DMC8 TN list.
Prompt Response Description
REQ PRT Request.
TYPE DCS Digital Cordless Set.
TN l s c
l
l s c u
Terminal Number for DMC8 card on IPE shelf or
Cabinet
V
irtual Terminal Number on an IPE shelf or Cabinet
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit
The print routine outputs the following format:
INDX Index # VTN lll s cc uu
where: Index # = Index number of virtual
TN.
Example
lll s cc uu = Virtual TN of unit.
Table 45: LD 81 - Print DCS features.
Prompt Response Description
REQ LST Request.
FEAT VSIT Feature Request - DECT visitors.
HMDN Xx / <cr> HoMe Directory Number. Specify a single HMDN or
print all HMDN on system.
Implementing and operating MSMN
DMC DECT Fundamentals August 2012 227