User's Manual
Prompt Response Description
MWUN 32 Maximum number of Wireless UNits – entry defaults
to 32 with no user input – value cannot be CHG'ed.
Note:
If MWUN = 32, CDEN automatically changes to 8D,
and prints as an 8D unit.
DMC8
Location of the actual DMC8. Assigns a TN to a DECT
Mobility Card located on an IPE shelf or cabinet.
l s c Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card
INDX
0. 509 DMC8 index to map the Virtual TN to a DMC8 TN.
Starting index on DMC8, each unit increments to the
next available unit.
VSIT
(NO) YES ViSITing DECT set. Determines the difference
between a local handset and a visiting handset. VSIT
available if the MSMN Package is unrestricted. YES =
visiting DECT set. NO = local DECT set.
HMDN
x...x HoMe Directory Number. Sets the DN as a valid
MCDN network DN. NMDN available if VSIT = YES.
Table 41: LD 10 - Copy DCS data block or data blocks.
Prompt Response Description
REQ: CPY 1 – 32 CPY n = The generation of new units stop when the
following occurs:
maximum index of 509 is reached on a single DMC8
or
VTNs on the system run out or
WRLS Licence limits reached.
All DCS must be on the same DMC8.
DMC8 l s c l Location of the actual DMC8 to copy on an IPE shelf
or cabinet.
Table 42: LD 10 - Remove DCS data block or data blocks.
Prompt Response Description
REQ: OUT 1-255 OUT X = Removing units stops when the maximum
index of 509 is reached on a single DMC8. All new
DCS must be on the same DMC8.
DMC8 l s c l Location of the actual DMC8 to out on an IPE shelf or
cabinet.
Installation and configuration
226 DMC DECT Fundamentals August 2012
Comments? infodev@avaya.com