User's Manual
See Figure 77: External housing mounting lugs on page 139
for details. Reposition
mounting lugs if necessary.
2. Drill mounting holes in the wall.
Use the drilling jig to align the holes.
3. Mount the external housing to the wall.
See
Figure 78: External housing wall mounting on page
139 for details. Use the
screws, and appropriate inserts, to fasten the housing to the wall.
Connecting the external housing wiring to the MDF
Consult the work order
, then perform the steps in Connecting the external housing wiring to
the MDF.
Figure 79: External housing MDF connection details
Note:
The BIX tip and ring connections shown in Table 36: External housing basestation to BIX
MDF connections on page 141
correspond to standard BIX designation. The first pair are
labelled T0 and R0. See Avaya Communication Server 1000M and Meridian 1: Large
System Installation and Commissioning (NN43021-310), chapter Planning and designating
the Modular Distribution Frame (MDF).
Connecting the external housing wiring to the MDF
1. Lead the building cable into the external housing.
Route the cable through the cable outlet in the external housing.
2. Secure the cable in the connecting box.
Use a cable tie-wrap.
3. Connect the external housing wiring from the connecting box to the MDF.
Note:
See Figure 79: External housing MDF connection details on page 140 and Table
36: External housing basestation to BIX MDF connections on page 141 for wiring
Installation and configuration
140 DMC DECT Fundamentals August 2012