User's Manual

For maximum line length before signal degradation occurs, use UTP Cat 5 cabling between
the basestation and the shelf or cabinet. If the line length exceeds 100 ohms for the 4610
basestation, an external power supply must be used.
The maximum distance when using external power with UTP Cat 5 cabling is approximately
1.7 km.
Figure 71: Basestation, MDF, and I/O panel details
Key
a RJ45 Connection Box
b MDF
c recommended UTP Cat 5 cable
d IPE shelf I/O connector panel
Installing basestation wiring to the MDF
1.
Connect one end of the NTCW10 cable into the basestation RJ45 jack.
Use the supplied cable.
2. Install the RJ45 Connection Box.
Use the NTCW10 cable length to measure the location of the RJ45 Connection
Box.
3. See
Table 35: Basestation RJ45 to BIX MDF connections on page 133 for
connection details.
Note:
Ensure that the cable is twisted pair from beginning to end.
Installation and configuration
132 DMC DECT Fundamentals August 2012