User's Manual
When a user hears the Welcome message, and presses 1 and #, for example, the users hears
the wave file AlarmConfirmation.wav.
There are 4 different types of menu options possible for eVBVM_L1_Menu_Type_str =
• *CONFIRM
• *SET
• *RESET
• *RECORD
CONFIRM
For menu type = *CONFIRM for confirmation of alarms, there are no entries possible in the
eVBVOICE_MENU_L2 table.
With the eVBVOICE application, users can confirm messages with a personal pincode
(DEV_PinCode_str in eKernel_device).
If a message that is sent contains a message that must be confirmed, the user can make a
call to the eVBVOICE application to confirm the alarm.
The user hears a welcome message when connected and must select the menu option for
confirmation of alarms (*CONFIRM). The user is prompted to enter his pincode
(eVBVM_L1_Menu_Wavfile_str ).
This pincode is related to a device configured in the DEVICE table in the configuration database
(DEV_PinCode_str in eKernel_device table).
The eKernel application checks the database for the devices related to this pincode, and
informs the eVBVOICE application of the number of devices. If the pincode is unknown in the
database, the "WrongPincode message" (eVBV_WrongPincode_str) plays.
If there are no alarms active for this pincode, the user hears a message that no messages are
active for this pincode (VBV_Nomess_str).
If the confirmation is successful, all the active alarms for all the devices related to this pincode
are cleared. The wave file entered in the eVBV_Confirm_str field plays.
If a wave file entered in the configuration tables does not exist, the wave file entered in the
eVBV_NoWavFile_str field plays.
It is not possible to confirm an alarm during an outbound call in the current release. When a
person receives a message through eVBVOICE, for example a call at home, the user cannot
confirm the alarm or alarms during the same call. In the current release you must make a new
call, particularly to confirm alarms.
SET and RESET
For menu type (eVBVM_L1_Menu_Type_str) = *SET and *RESET (set and reset of alarms),
a link to the eVBVOICE_MENU_L2 table is necessary.
Introduction