User's Manual

When the eTM_HA is paused or stopped, the routine that verifies and restarts the process is
temporarily interrupted.
This usually occurs during maintenance of one of more of the programs that are guarded by
the eTM_HA. This temporary condition is shown in the logging.
A system administrator can also terminate a task from within the eTM_HA environment using
a Terminate process API-call.
Note:
Using the Terminate process API-call can cause data loss, as this does not provide any
graceful cleanup or shutdown of the associated program.
To terminate a process in the Task Manager, use the Kill task menu option as shown in Figure
86: Kill Task on page 82. The Kill task option is available only when the tree-view is expanded
and the mouse is right-clicked on the PID:xxxxxxxxxx line.
Figure 86: Kill Task
Note:
When the eTM is running, the system relaunches the terminated tasks within 10 seconds.
When the eTM form is closed through the control box on the right top of the form, the application
does not shut down, but is instead minimized to an icon in the system tray. This function is
designed to prevent the user from accidentally closing the eTM and associated tasks. This
approach is similar to monitoring applications of other vendors, such as the Apache Monitor
or the SQL Server Service Manager.
Shutting down eTM_HA
The eTM can be shut down by means of the pop-up menu shown in
Figure 69: Open Task
Manager on page 65, using the Exit menu option.
Important:
Avaya recommends that you close applications using shut down or exit/close options in the
applications, to ensure a clean shutdown. This helps to protect volatile data, properly close
Module - eTM_HA
82 DECT Messenger Installation and Commissioning — Book 2 March 2012
Comments? infodev@avaya.com