User's Manual
Chapter 38: Table: eLOCATION
eLOCATION parameters
eLOC_Site_id_n
This parameter refers to the site identifier, as defined in eKERNEL_SITE table. The eMODULE
instance is uniquely defined through a site and an area, so eLOC_Site_id_n and
eLOC_Area_id_n form a unique key in the table.
An authorized of an entry typically found in this field is as follows: 1
eLOC_Area_id_n
This parameter refers to the area identifier, as defined in eKERNEL_AREA table. The
eMODULE instance is uniquely defined through a site and an area, so eLOC_Site_id_n and
eLOC_Area_id_n form a unique key in the table. One instance of eLOCATION module can
work with only one SIP DECT system. Each SIP DECT system should have it own eLOCATION
instance for location detection.
An authorized of an entry typically found in this field is as follows: 1
eLOC_LA_address_str
If SIP DECT is used, this parameter refers to the IP address of the DAP Controller that is
handled by the instance of the eLOCATION module. Refer to the system administrator of the
DECT Messenger Installation and Commissioning — Book 2 March 2012 343