For more information, see the user manual of the internal serial watchdog page 9 till 13.
An authorized of an entry typically found in this field is as follows: 0x21
CFG_INRQS_id_n
This field specifies a value that is used internally by eKERNEL, and you must not change the
value unless explicitly instructed to do so. The value stored in CFG_INRQS_id_n is used to
generate unique numbers to incoming message requests. Manipulation of this value can result
in system malfunction. The value is used to generate unique keys in the Messenger_DATA
database table RQS_IN. Resetting the value without cleaning up RQS_IN can result in system
failure and is unsupported.
Important:
Because table values are, for performance reasons, retrieved at startup of eKERNEL, and
committed at close down of eKERNEL, never stop the eKERNEL using any method other
than gracefully shutting down the application with the close button. Abnormal shutdown can
result in problems when the system is started. Avaya recommends the use of a UPS.
Problems due to system power failure are unsupported.
An authorized of an entry typically found in this field is as follows: 2392 (never change the
current value manually)
CFG_OUTRQS_id_n
This field specifies a value that is used internally by eKERNEL and you must not change the
value unless explicitly instructed to do so. The value stored in CFG_OUTRQs_id_n is a number
that is used to generate unique numbers to outgoing message requests. Manipulation with this
value can result in system malfunction. The value is used to generate unique keys in the
Messenger_DATA database. Resetting the value without cleaning up the appropriate database
can result in system failure and is unsupported.
Important:
Because table values are, for performance reasons, retrieved at startup of eKERNEL, and
committed at close down of eKERNEL, never stop the eKERNEL using any method other
than gracefully shutting down the application with the close button. Abnormal shutdown can
result in problems when the system is started. Avaya recommends the use of a UPS.
Problems due to system power failure are unsupported.
An authorized of an entry typically found in this field is as follows: 4 (never change the current
value manually)
CFG_Comments_str
This field provides space for the administrator to enter comments, such as reminder
information, describing, for authorized, the full name of the site.
eKERNEL_SITE parameters