User's Manual
An authorized of an entry typically found in this field is as follows: COM01
INPGM_Settings_str
This value must be set to blanks for the modules eAPI, IO, SMTP_server, VBVOICE and
eWEB.
The value must be set to the so-called COM-setting for the module eCAP (RS-232 interfaces).
The settings must be a supported combination of baud-rate, parity, data-bits, and stop bits.
The value must off-course match the settings of the attached alarm system.
An authorized of an entry typically found in this field is as follows: 9600,N,8,1
INPGM_AutoCreateGRP_b
This value is an important value for relation to eKERNEL_GROUP and
eKERNEL_GROUP_MEMBER and eKERNEL_DEVICE.
This value defines whether alarms from the defined system must automatically create a group
in eKERNEL_GROUP table and a group member in the eKERNEL_GROUP_MEMBER table
and a device in eKERNEL_DEVICE table. In most cases, the alarm system is unaware of the
range of groups and devices and need manual configuration. In this case, the value is 0
(False).
In some cases, external parties can provide a valid DECT number in alarm datastreams. This
can be because the external parties are aware of the infrastructure and number scheme of the
DECT extension, or have administrative tools available in the alarm systems that allow them
to adjust the alarm information according to the DECT Messenger number scheme. This
means the alarm systems are capable of sending alarms containing correct destination
numbers. Otherwise, they can provide a valid DECT number in their alarm data streams.
When the alarm system provides valid device names in the alarm string, you can choose to
eliminate the need of defining the infrastructure over again in the eKERNEL_GROUP,
eKERNEL_GROUP_MEMBER and eKERNEL_DEVICE tables.
Important:
Carefully evaluate whether you trust the external parties in ALWAYS providing valid
information. If you do, set the value to 1 (True), indicating automatic creation of groups,
group members, and devices.
Avaya recommends using a value of 0 (False) unless you are fully aware of the risks involved,
for authorized, in receiving invalid devices.
If you activate this function, you must indicate in the fields INPGM_Default_DEV_OUTPGM_str
and INPGM_Default_DEV_OUTPGM_facility_str the additional parameters that are needed
for the auto—configuration process.
eKERNEL_INPGM parameters
DECT Messenger Installation and Commissioning — Book 2 March 2012 321