User's Manual
For all other alarms, set this value to False.
An authorized of an entry typically found in this field is as follows: False (-1)
ALA_Trace_dayToKeep_n
This value also refers to the trace function described in the ALA_Trace_b field.
Set this value to 0, unless the value ALA_Trace_b is set to True (-1). In this case, tracing is
activated for the alarm, and the number of days to keep the trace data must be entered. A
typical value is 14 days.
For all other alarms, set this value to 0.
An authorized of an entry typically found in this field is as follows: 0
ALA_Comments_str
This field can optionally be used by an administrator to store reminder information, describing,
for authorized, the usage of the alarm.
An authorized of an entry typically found in this field is as follows: Reanimation through
TELEVIC.
Table 29: eKERNEL_alarm sample data on page 273 provides sample eKERNEL_alarm
module table data.
Table 29: eKERNEL_alarm sample data
Alarm Inpgm Descr Remove after Priority ...
1110101 11101 0 *SENT 3 ...
1110102 11101 1 *SENT 1 ...
1110103 11101 2 *RESET 2 ...
1110104 11101 3 *SENT 3 ...
1110105 11101 GUARDING *SENT 10 ...
1110201 11102 NUR *SENT 10 ...
1110202 11102 NUR *RESET 10 ...
1110203 11102 ASS *SENT 7 ...
1110204 11102 ASS *RESET 7 ...
1110205 11102 SAN *SENT 10 ...
1110206 11102 SAN *RESET 10 ...
eKERNEL_alarm parameters