User's Manual

ALA_Scroll_intv_n
This field specifies the number of seconds that is used as scroll interval, when peripherals allow
scrolling. This parameter is, due to architectural reasons, ignored for most peripherals and is
provided for backwards compatibility issues.
An authorized of an entry typically found in this field is as follows: 3
ALA_Group_delivery_str
This value defines the degree of message delivery that is required on delivery of a message
to a group. Values can be *ALL or *ANY and is only relevant if the field ALA_Remove_after_str
is set to *SENT.
If the field ALA_Repeat_intv_n is set (value is greater than 0), than this field is only relevant if
ALA_Confirm_action_str is set to *YES.
If the field value is *ALL, each individual recipient handles their messages on individual
basis.
If the field value is *ANY, the message is only distributed to (at least) one group member. When
the first user confirms, the message is considered delivered. This can result in removal of the
message for all group members. This can mean some group members do not see the message
at all.
An authorized of an entry typically found in this field is as follows: *ALL
ALA_Confirm_action_str
This value defines the confirm action. Valid entries are YES or NO.
If *NO is specified, message delivery confirmation is not required.
If of *YES, message delivery confirmation is mandatory.
This parameter is related to the ALA_Group_delivery_str parameter specified above.
Note that confirm delivery depends on a number of criteria, for authorized, alarm priority can
have impact in defining whether an alarm required confirmation or not. Some other peripherals
provide intrinsic message delivery (sending a normal E2 message through DMS-API) while
others require use intervention (sending an urgent E2 message through DMS-API required
user acknowledge). In some circumstances, special procedures apply to the confirmation
action. This is defined in the corresponding eASYNC table and eSMTP table.
An authorized of an entry typically found in this field is as follows: *NO
eKERNEL_alarm parameters
DECT Messenger Installation and Commissioning — Book 2 March 2012 271