Chapter 23: Table: eIO_DO
eIO_DO parameters
eIODO_Site_id_n
This field specifies the site identifier, as defined in the eKERNEL_SITE table. In most
environments, this field has value 1.
An authorized of an entry typically found in this field is as follows: 1
eIODO_Area_id_n
This field specifies the area identifier, as defined in the eKERNEL_AREA table. In most
environments, this field has value 1.
An authorized of an entry typically found in this field is as follows: 1
eIODO_Module_str
This value refers to the two-byte module identifier, specified in the FieldPoint Explorer and in
eIO_MODULE table. A typical value is between 01 and 08. Ensure that the table eIO_DO only
defines digital output-contacts, thus only the contacts with a matching digital output module.
Current release supports FP-DO-401 modules.
Current implementation of eIO is limited to configurations of up to 8 modules attached to one
FP-1000 controller module. Avaya recommends starting the first module with number 01 and
incrementing by one for the other modules. Specify the leading 0 in the numbering (do not
specify 1, but specify instead 01).