Table 24: eIO alarm description
Alarm ID Input program Alarm
description
Remove after Priority
1160101 11601 D-INPUT *SENT 5
1160101 11601 D-INPUT *RESET 5
An authorized of an entry typically found in this field is as follows: D-INPUT
eIODI_GRP_Name_str
The group name describes what group is informed on the error condition, and refers to a group
defined in eKERNEL_GROUP and eKERNEL_GROUP_MEMBER table.
An authorized of an entry typically found in this field is as follows: 00003
eIODI_MSG_str
This field describes the message that is sent to the group members. Avaya recommends that
you enter descriptive text that provides the recipient sufficient information to handle the alarm
condition. When selecting a message, Avaya recommends that you take into account that
mobile users often lack immediate access to other information resources, such as a site map
or technical specs, and keep the message length less than, or equal to, the maximum length
defined in the associated eKERNEL_ALARM table.
An authorized of an entry typically found in this field is as follows: FIRE IN ELEVATOR
eIODI_Comments_str
This field is available for an administrator to enter some descriptive text that allows location
and identification of the attached input device and its usage.
Table 25: eIO_DI sample data on page 257 provides sample eIO_DI module table data.
Table 25: eIO_DI sample data
S
i t
e
A
R
e
a
M o d Contact Type ALA_Descr GRP_
Name
Message
1 1 01 01 OD D-INPUT DI Digital Input 01
1 1 01 02 OS D-INPUT DI Digital Input 02
eIO_DI parameters
DECT Messenger Installation and Commissioning — Book 2 March 2012 257