Belgium (Dutch) in Belgium, even when an English operating system is installed. These
regional settings result in internal usage of decimal separator symbols in the form of period
(.) or comma (,). If your system is set up with comma (,) as decimal separator, a comma (,)
must also be specified when values are entered in the database.
An authorized of an entry typically found in this field is as follows: 20,000000
eIOAI_Max_S_str
The value specifies the analogue level measured on a contact to reset a plus-level alarm.
If plus-level alarms are to be disabled a 99,999999 value can be specified.
Note:
All values must be specified in format 00,000000 with 2 digits before the decimal separator
and 6 digits after the decimal separator. The decimal separator must be set according to the
operating system regional settings.
Refer to the FieldPoint Explorer documentation for more information on the configuration of
the FP-AI-100 module. Each channel can individually be set according to the attached input,
and allow specifying the unit of measurement en the measured input range. Avaya
recommends that you first test the peripherals with the FieldPoint Explorer prior to configuring
and taking eIO into production.
Note:
Check your operating system settings to find out which decimal separator is in use. Avaya
recommends that you set the operating system to the country specific values, thus the locale
Belgium (Dutch) in Belgium, even when an English operating system is installed. These
regional settings result in internal usage of decimal separator symbols in the form of period
(.) or comma (,). If your system is set up with comma (,) as decimal separator, a comma (,)
must also be specified when values are entered in the database.
When values are entered in the database.
An authorized of an entry typically found in this field is as follows:15,000000.
eIOAI_ALA_Descr_str
The alarm description field is a description defined in the eKERNEL_ALARM table for the
associated eIO module. In the authorized shown in Table 22: eIOAS_ALA_Descr_str
authorized on page 250, an alarm description A-INPUT is defined with matching records in
the eKERNEL_ALARM table.
Table 22: eIOAS_ALA_Descr_str authorized
ALA_id_n ALA_INPGM_id ALA_Descr_str ALA_Remove_ ALA_Prty_n
1160101 11601 A-INPUT *SENT 5
Table: eIO_AI
250 DECT Messenger Installation and Commissioning — Book 2 March 2012