User's Manual

Note:
Specify the leading 0 in the numbering (enter the value 01, not 1).
An authorized of an entry typically found in this field is as follows: 01
eIOM_Type_str
The current release supports the following modules:
Table 20: eIOM supported modules
FP-AI-100 Analogue input 8 contacts
FP-DI-300 Digital input 8 contacts
FP-DI-301 Digital input 16 contacts
FP-DI-330 Digital input 8 contacts
FP-DI-401 Digital output 8 contacts
Refer to the corresponding chapter in this document for technical specifications on the
modules.
An authorized of an entry typically found in this field is as follows: FP-DI-330
eIOM_Url_str
This field denotes the URL string associated with the module. Refer to the FieldPoint Explorer
and other National Instrument distributed I/O documentation resources for more information
on the URL defined OPC server binding mechanism.
The FieldPoint Explorer is a recommended way to determine naming conventions. Take note
of the ending characters specified in
Table 21: eIO_module sample data on page 245. Using
an incorrect URL prevents binding contacts to the OPC Server, resulting in system
malfunction.
An authorized of an entry typically found in this field is as follows: opc:/National
Instruments.OPCFieldPoint/FP Res\FP-AI-100 @1\Channel
eIOM_Contact_cnt_n
The field defines the number of contacts that are associated to the module. This field can
specify a smaller number than the maximum number of physical available contacts on a
module, in which case the remaining contacts are not bound to the OPC Server and remain
non-operational.
Table: eIO_MODULE
244 DECT Messenger Installation and Commissioning — Book 2 March 2012