If more than one address must be polled, the addresses must be separated with a ^ sign. In
this release, only a point to point link is supported, so only one address can be specified.
An authorized of an entry typically found in this field is as follows: 2
eESPA_LocalAddress_n
This field specifies the address of the local espa interface.
An authorized of an entry typically found in this field is as follows: 1
eESPA_ExternalAddress_n
This field specifies the address of the remote station.
One eESPA interface is linked with one area, so is linked to only one remote station. If more
than one station can receive are sent espa alarms, more areas must be configured in the
configuration database.
An authorized of an entry typically found in this field is as follows: 2
eESPA_DataId_Group_str
Use this field to set the relationship between the DECT Messenger Device or Group and the
data identifier of the espa record that specifies the call address if eESPA acts as input program,
so it is only relevant if eESPA receives external data from the espa infrastructure.
If the eESPA module acts as input program:
The eESPA module receives espa records. Each espa record received must be translated to
a valid message request, and sent to the eKERNEL application.
The eESPA_DataId_Group_str field specifies the Data Identifier (normally 1) of the espa record
that specifies the group. This group refers to the field GRP_Descr_str of eKERNEL_GROUP
table.
In the following authorized, data identifier 1 (call address) is defined as
eESPA_DataId_Group_str.
Table 15: Espa record: SOH1STX1US12345RS2USThe
messageRS3US9RS4US3RS6US3ETXBCC
(SOH)
Start of header
STX Start of text
ETX End of text
eESPA parameters
DECT Messenger Installation and Commissioning — Book 2 March 2012 227