User's Manual
If the field eCAPG_Ala_Descr_start_n is non-0, the eCAPG_Ala_Descr_len_n must be non-0
as well.
An example of an entry typically found in this field is as follows: 1
eCAPG_Ala_Descr_field_n
This field specifies the occurrence number of the field that denotes alarm description, and only
applies when a field separator is defined. In this case, no positional definition is active.
The field must be 0 when no such definition is active.
A positive value indicates the field number. For example, when the field separator is / and the
datastream is 001/02/ABC, the value of 1 returns 001 as alarm description, a value 2 would
return 02 as alarm description and 3 would return ABC as alarm description.
An example of an entry typically found in this field is as follows: 0
eCAPG_Dft_GRP_Name_str
This field is used to provide a default group name, in the event that no value can be retrieved
from the available datastream. In this case, the same value is used for all alarms generated
through this eCAP generic interface instance.
The value N/A must be specified if this field is not used.
An example of an entry typically found in this field is as follows: N/A
eCAPG_Dft_Msg_str
This field is used to provide a default message, in the event that no value can be retrieved from
the available datastream. In this case, the same value is used for all alarms generated through
this eCAP generic interface instance.
The value N/A must be specified if this field is not used.
An example of an entry typically found in this field is as follows: N/A
eCAPG_Dft_Ala_Descr_str
This field is used to provide a default alarm description, in the event that no value can be
retrieved from the available datastream. In this case, the same value is used for all alarms
generated through this eCAP generic interface instance.
The value N/A must be specified if this field is not used.
An example of an entry typically found in this field is as follows: N/A
eCAP_generic parameters
DECT Messenger Installation and Commissioning — Book 2 March 2012 203